Specifications
PJ-1614NXE PJ-2216NXE Maintenance Manual 5 Self-Diagnosis Function
5-45
5.9.1 CR Motor Endurance Menu
This menu performs endurance running for the CR motor.
You can perform carriage stroke according to your desired setting. The available setting is shown below.
TIP
• The operation speed is 291.66cps.
• If the number of endurance running cycles is set to -1, the carriage continuously repeats stroking until a key input
is given from the operation panel.
• The maximum counter value for endurance running cycles is 99999999 (up to 8-digit number). If the number of
cycles exceeds the maximum value, the counter is reset to 0.
• The maximum and minimum values of the carriage stroking distance are as follows.
• MAX: 2,066 mm (64-inch spec), 2,637.478 mm (87-inch spec) from origin
• MIN: 8mm from origin
Table 5-13 Set Item in CR Motor Endurance Menu
Set item Contents Set value Remark
Number of endurance running
cycles
Set the number of endurance
running cycles
-1 to 10000