5.9.1 CR Motor Endurance Menu
This menu performs endurance running for the CR motor.
You can perform carriage stroke according to your desired setting. The available setting is shown below.
TIP
The operation speed is 291.66cps.
If the number of endurance running cycles is set to -1, the carriage continuously repeats stroking until a key input
is given from the operation panel.
The maximum counter value for endurance running cycles is 99999999 (up to 8-digit number). If the number of
cycles exceeds the maximum value, the counter is reset to 0.
The maximum and minimum values of the carriage stroking distance are as follows.
MAX: 2,066 mm (64-inch spec), 2,637.478 mm (87-inch spec) from origin
MIN: 8mm from origin
Table 5-13 Set Item in CR Motor Endurance Menu
Set item Contents Set value Remark
Number of endurance running
cycles
Set the number of endurance
running cycles
-1 to 10000