Specifications
PJ-1614NXE PJ-2216NXE Maintenance Manual 5 Self-Diagnosis Function
5-17
5.5.1 Skew Check Menu
In this menu, you can perform paper feed and check the degree of skew in the paper feed operation by
means of the sensors.
When you select this item from the Adjustment menu, the machine feeds the paper by one pass and
checks for paper feed skew by comparing the paper edge positions before and after the paper feed
detected by the sensors.
NOTE
Before performing skew check, ensure that the paper is set correctly.
5.5.2 Voltage Input Menu
This menu is used to input the head voltage.
The head voltage value is used to determine the head-driving voltage and correct the head temperature.
To input the head voltage, follow the steps below.
1. Using the keys in the operation panel, enter an appropriate parameter value for the head voltage.
Table 5-5 Skew Amount Specification
Condition Specification
Right side 0mm
Left side 5mm or less