PJ-1614NXE PJ-2216NXE Maintenance Manual 4 Part Replacement
4-71
4. Remove the nut retaining the ink level switch.
5. Remove the ink level switch.
6. Replace the bottle cap.
7. To install the removed components, reverse the removal procedure.
4.9.3 Replacing Waste Fluid Bottle, Bottle Cap, Waste Ink Cap
Assembly, and Waste Fluid Level Switch
NOTE
Before replacing the waste fluid tank, extract all waste fluid from the existing tank.
Always ensure that there is no residual waste fluid in the waste fluid tube.
1. Disconnect the waste fluid tube from the waste ink cap assembly.
2. Remove the bottle cap from the waste fluid bottle.
3. Remove the waste ink cap assembly from the bottle cap.
No. Part name
1 Bottle cap
2 Ink supply pipe
3Nut
4 Ink level switch
1
2
3
4