Specifications
PJ-1614NXE PJ-2216NXE Maintenance Manual 4 Part Replacement
4-65
CAUTION
•
••
• When connecting and disconnecting the FFC type cables to/from the
TERM_PUMP board assembly connectors, always pull or push the cables
straightforwardly.
Pulling or pushing them slantwise may damage/short/break the terminals in the
connectors, resulting in breakdown of the on-board devices.
3. Remove the six screws retaining the TERM_PUMP board assembly.
4. Replace the TERM_PUMP board assembly.
5. To install the removed components, reverse the removal procedure.
4.8.9 Replacing Safety Valve Assembly
1. Disconnect the tube from the safety valve assembly.
Table 4-8 Connectors to TERM_PUMP Board Assembly
No. Connector No. # of pins
Colo
r
Connect to Remark
1 J1 30 White SUB board Lock type
2 J2 2 Blue Ink pump
3 J3 2 White Ink pump
4 J4 2 White Ink pump
5 J5 2 White Ink pump
6 J6 2 White Ink pump
7 J7 2 White Ink pump
8 J8 2 White Ink pump
9 J11 2 White Two-way solenoid valve
10 J12 3 White Air pump Lock type
11 J13 2 White Bimor pump
12 J14 5 White PRESS_SENS