Specifications
PJ-1614NXE PJ-2216NXE Maintenance Manual 4 Part Replacement
4-63
2. Remove the four screws retaining the air chamber.
3. Replace the air chamber.
4. To install the removed components, reverse the removal procedure.
4.8.6 Replacing Two-way Valve
1. Disconnect the two-way valve connector from the TERM_PUMP board assembly.
2. Disconnect the tubes from the two-way valve.
3. Remove the two screws retaining the two-way valve.
4. Replace the two-way valve.
5. To install the removed components, reverse the removal procedure.
4.8.7 Replacing PRESS_SENSE Board Assembly
1. Disconnect the connector and tubes from the PRESS_SENSE board assembly.
No. Part name
1Tube
2 Two-way valve-retaining screw (M3×4)
3Two-way valve
2
3
1