Specifications

PJ-1614NXE PJ-2216NXE Maintenance Manual 4 Part Replacement
4-61
4.8.3 Replacing Bimor Pump
1. Disconnect the bimor pump connector from the TERM_PUMP board assembly.
2. Disconnect the tubes from the bimor pump.
3. Remove the two screws retaining the pump bracket 2.
4. Remove the pump bracket.
5. Remove the two screws retaining the bimor pump.
6. Replace the bimor pump.
7. To install the removed components, reverse the removal procedure.
No. Part name
1Tube
2 Pump bracket 2-retaining screw (M3×5)
3 Pump bracket 2
No. Part name
1 Bimor pump
2 Bimor pump-retaining screw (M4×30)
2
1
3
1
2