Specifications

Falcon II Outdoor series printers – Maintenance Manual
61
AP-74065, Rev. 1.0, 21/11/03
Step 9 : Stick onto the sensor a sensor insul. patch.
1 = sensor insul. patch 2 = assembly hole
Step 10 : Reinstall all parts in the opposite order of the removal procedure.
Notes :
¾ During reinstallation of the plate, make sure there are no cables stuck.
4.3.2.3. Replacing the fixer (Heater B1 and Heater B2) on a Falcon II Outdoor 4H printer
Before replacing the fixer, make sure to have following items:
¾ 50” model : Fixer B1 50 (EY-80348) and Fixer B2 50 (EY-80349)
¾ 64” model : Fixer B1 64 (EY-80338) and Fixer B2 64 (EY-80339)
¾ 87” model : Fixer B1 87 (EY-80358) and Fixer B2 87 (EY-80359)
¾ Isolation tape (AP-51210)
¾ Plot platform calibre (TL-80200)
To replace the fixer on a Falcon II Outdoor 4H printer, please follow the instructions mentioned below.
Step 1 : Remove side cover L.
Step 2 : Remove side cover R.
Step 3 : Remove the front cover.
Step 4 : Remove the Y rail cover.
Step 5 : Remove the front paper guide.