AP-74065, Rev. 1.0, 21/11/03
Step 7 : Connect up the tubing in the manner shown in the figure below.
1 = Tube connecting to the waste fluid tube 2 = Tube connecting cap 3
3 = Tube connecting to cap 1
Step 8 : Use a linking tube to connect the new-part pump tube (DF-43951) to the tube connecting cap 2.
1 = Tube connecting to waste fluid side 2 = Tube connecting to cap 2
3 = Tube connecting to cap 4 4 = Newly-added pump tube (DF-43951, length = 40 mm)
5 = 2 tube for linking
Step 9 : Insert into the waste fluid tubes from the pumps a piece of tube (DF-43951; 15 cm).
1 = piece of tube (15 cm)