Specifications
Falcon II Outdoor series printers – Maintenance Manual
258
AP-74065, Rev. 1.0, 21/11/03
Step 2 : Following the instructions in "Self-Diagnosis Functions" to start the equipment up in the self-diagnosis mode and
release the head lock.
Step 3 : Disconnect the tubes to the heads.
Step 4 : Remove the waste tubes from there connector.
1 = connection to the heads 2 = waste tube connection
Step 5 : Remove the pump assemblies.
Step 6 : Reinstall the new pump assemblies.
Step 7 : Reconnect the tubes.
87” Falcon II Outdoor 2 heater 87” Falcon II Outdoor 4 heater