Specifications
Falcon II Outdoor series printers – Maintenance Manual
253
AP-74065, Rev. 1.0, 21/11/03
Step 9 : Adjust the P_EDGE sensor control shown in the following figure so that the values displayed in the operation
panel become the adjustment value.
¾ Control R693: Rough adjustment
¾ Control R694: Fine adjustment
1 = Volume R693 2 = Volume R694
(2) LOW level (without media) A/D value check
Step 1 : Adjust the A/D value of the HIGH level following the "(1) HIGH level A/D value adjustment" procedure.
Step 2 : Align the cutter and the right edge of the standard media by moving the carriage.
1 = Razor Blade
Notes :
¾ Perform the following if the A/D values of the edge sensor are not the adjustment
value.
1 ) Checking the installation angle (about 15°) of the P_EDGE sensor assembly
2 ) Replacing the P_EDGE sensor assembly
3 ) Re-inspecting the Mainboard assembly
Step 3 : Make sure that the values displayed in the operation panel are as shown below.
¾ In hexadecimal number : 30 to 0
¾ In decimal number : 48 to 0