Specifications

Falcon II Outdoor series printers – Maintenance Manual
24
AP-74065, Rev. 1.0, 21/11/03
2.5. POSITION AND FUNCTION OF THE HEATING ELEMENTS
2.5.1. Falcon II Outdoor 2 heater printers
Heater element Temperature Function
Pre-heater (Heater A) 20 – 50°C
Open the pores to make the media more receptive for
eco-solvent or eco-solvent plus™ ink.
Dryer (Heater D) 20 – 50°C
Applying heating immediately after printing improves
ink/media anchorage.
The dryer helps to make the media touch-dry before it
reaches the automatic take-up system.
2.5.2. Falcon II Outdoor 4 heater printers
Heater element Temperature Function
Pre-heater (Heater A) 20 – 50°C
Open the pores to make the media more receptive
for eco-solvent or eco-solvent plus™ ink.
Fixer (Heater B) 20 – 70°C
To establish optimum fixation onto the media
(coated and uncoated).
Optimizes the dot gain control.