Specifications
Falcon II Outdoor series printers – Maintenance Manual
139
AP-74065, Rev. 1.0, 21/11/03
4.11.3. Replacing the waste bottle box sensor assembly (F2O 2H)
Step 1 : Follow the instructions in "Replacing the waste fluid bottle assembly" to remove the waste fluid bottle assembly.
Step 2 : Remove the waste liquid BOX sensor assembly connector from the rear side cap R.
1 = Rear side cap R 2 = Waste liquid BOX sensor assembly connector
Step 3 : Remove the screws (3 at the front and 12 at the right and left) fixing the waste liquid bottle cover.
1 = Waste liquid bottle cover 2 = Screws (M3x6)
Step 4 : Remove the waste liquid bottle cover.
Step 5 : Remove the screws (2) fixing the waste liquid sensor installation board.
1 = Screws fixing the waste liquid sensor installation board (M3x6)