AP-74065, Rev. 1.0, 21/11/03
Step 14 : Replace the CR tape power cable.
1 = Tube push plate 2 = Cable clamp
2 = Pipe clamp 3 = Coupling, O-ring, coupling screws
4 = Screws fixing tube push plate (M3x8) 4 = Screws fixing tube cramp (M3x20)
Step 15 : Reinstall all parts in the opposite order of the removal procedure.
Notes :
¾ The CR tape power cables must be bundled during installation so that they can not
move.
¾ The edge of the tube push plate must be upside when installed.
¾ You should soak the O-ring in cleaning liquid once gain before installing it.