Technical data

13
Operation
1) Which operation mode is basically needed?
»MODE«
Should my MC-3+ work as clock generator (»INTERNAL«), as clock distributor (»EXTERNAL«) or as audio
signal re-clocker (»RE-CLOCK«)?
2) Which reference do I need for my clocking application?
»REFERENCE«
3) Do I need different clock rates at the same time?
»CLOCK
MULTIPLIERS«
After these general decisions are made, your MC-3+ is configured for optimal operation in your set-up. Due to the fact that the
system monitors for useful function combinations, maloperation is not possible.
So, let‘s have a look to the individual functions.
Selecting Modes
This setting example shows the MC-3+ locked to its internal ultra-low jitter clock base generating output clocks of 44.1 kHz at
any available output. This is the factory default setting.
MODE
RE-CLOCK
EXTERNAL
INTERNAL
REFERENCE
S/P-DIF op
S/P-DIF co
88.2
48.0
44.1
32.0
192.0
96.0
176.4
10.0M
WCLK
INTERNAL + 10.0M
AES3/11
x 256
x 4
x 2
x 1
CLOCK MULTIPLIERS
1 5432
MODE
RE-CLOCK
EXTERNAL
INTERNAL
x 256
x 4
x 2
x 1
CLOCK MULTIPLIERS
1 5432
REFERENCE
S/P-DIF op
S/P-DIF co
88.2
48.0
44.1
32.0
192.0
96.0
176.4
10.0M
WCLK
INTERNAL + 10.0M
AES3/11