TP-6000 SERIES USER’S MANUAL TOUCH PANEL POS SYSTEM Rev.
SOME IMPORTANT NOTES FCC NOTES This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions manual, may cause interference to radio communications. It has been tested and found to comply with limits for a Class A digital device pursuant to subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against interference when operated in a commercial environment.
TABLE OF CONTENTS BRIEF INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1 THE USER’S MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 THE PRODUCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Standard Features . . . . . . . . . . . . . . .
INSTALLING CASH DRAWERS . . . . . . . . . . . . . . . . . . . . . . . . 3 - 6 WALL MOUNTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 7 LOCATION FOR INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . 3 - 7 USING THE TOUCH POS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 1 APPLICATION ENVIRONMENT . . . . . . . . . . . . . . . . . . . . . . . . . 4 Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BRIEF INTRODUCTION THE USER’S MANUAL The purpose of this manual is to guide the user in the initial installation and general use of the Posiflex fully integrated compact touch terminal system with touch panel input. TP6000 series is a product group of fully integrated PC based touch terminal systems. However, this manual does not intend to explain any application software that may be supplied with the TP6000 systems.
f) Height adjustment: the high / low adjustment gives 20 mm difference in height g) Resistive type touch panel h) Extra long life touch panel that endures 10 million up to 35 million touches in one location i) Spill proof water resistant structure allows for easy cleaning j) Easy maintenance construction k) Various I/O ports supported, including: 1. 1 PS/2 KB port 2. 1 PS/2 mouse port 3. Serial Ports: 1 for TP6XXXR of system revision A. 2 for TP6XXXP of system revision A.
q) Touch control functions: left/right mouse buttons, double click, drag & drop r) Touch sound can be pitch adjusted and enabled/disabled by software control s) High resolution touch sensor: 1024 x 1024 t) u) v) w) x) y) DRAM memory can extend to 1GB Dual display support under OS’s supporting multiple display output VGA memory size selectable by software (up to 64 MB) Integrated structure for optional MSR Software selectable MSR parameters 2 color choices: beige or charcoal OPTIONAL ITEMS Note: The factor
TP6000 USER’S MANUAL 1 - 4
PARTS IDENTIFICATION FRONT VIEW MSR Unit Display Screen + Touch Panel Main Unit Adjustable Stand Assembly The MSR unit is optional for both 12” and 15” models. The orange/green LED in the logo area is multipurpose. Please refer to the paragraph discussing the LED indication in the “USING THE TOUCH POS” chapter of this manual.
SIDE VIEWS Right Side View Latch Hole For Cable Cover Push In This Direction To Adjust The Tilt Angle Of The Display Panel Lock/Release Lever Left Side View Push Down To Switch The Power ON/OFF Latch Hole For Cable Cover Slide Switch For Power On/Off Control TP6000 USER’S MANUAL 2 - 2
REAR VIEW Lock/Release Button To Detach The Main Unit Optional MSR Unit Lock/Release Lever Cable Exit REAR VIEW OF MAIN UNIT Service Window Matching Pegs Cable Exit Cable Cover Removal Hollow Of Cable Cover Note: The contents in the service window may evolve as technology progresses. Please consult your dealer for applicability.
ADJUSTABLE STAND ASSEMBLY Matching Holes Stand Base Lock/Release Lever BOTTOM OF STAND ASSEMBLY Base UPS Battery Cover Lock/Release Button For Main Unit Cable Passage Cover Cable Exit Stand TP6000 USER’S MANUAL 2 - 4
INSTALLATION GUIDES CAUTION: Before installing any cables or peripherals to the terminal, please always make certain that the system is turned off and the external power source is removed to prevent electric hazard! Never touch any pins within the connectors or circuits to avoid high voltage hazard or electrostatic discharge. Failure to follow this caution may cause damage to the unit.
PREPARING STAND ASSEMBLY Take the adjustable stand assembly and turn it up side down to show the bottom of the base. 2 Sets of 4 Matching Holes Screws Cable Passage Cover Adjustable Stand Now, remove the 2 screws on the cable passage cover and lift the cable Lock/Release passage cover away from the base, to Lever show the passage.
INSTALLING UPS BATTERY UPS Battery Removed Battery Cover Place the optional UPS battery in the battery compartment (shown top left). Screw on the battery cover and route the battery cable through the base. Please enable the UPS features in the software settings before use. ROUTING THE CABLES Place all required cables into the cable passage. Insert one end of the cable passage cover under the battery cover and replace the two screws. Be sure not to damage any of the cables during this operation.
PREPARING THE MAIN UNIT On the back of the main unit, there are 4 matching pegs and a service window. Push the service window open, in the direction indicated in the picture. Below, one can find a button cell battery socket, a 1 x 3 header (JP10) with 1 jumper and a 2 x 3 header (JP8) with 2 jumpers. Service Window 4 Matching Pegs Push Open To The Right This battery socket requires a 3V button cell Lithium battery (CR2032) to support the system clock.
toward the upper round part of the hole and make sure that all pegs have been properly seated. Then slide the main unit down to move the pegs into the narrow section of the slot until the rear latch clicks. Note that all the cables come out of the stand from the lower edge and won’t get trapped by this mounting operation. If later on you want to remove the main unit from the stand, you’ll have to press down the lock/release button on back of the stand when lifting the main unit.
CONNECTING CABLES Connect the required cables to the appropriate connectors. Please make sure that each connector is connected to the right port with the correct orientation. Some connectors, such as the LAN connector, the external FDD connector, the power connector, the cash drawer connector, and the COM4 connector for the conversion cable have to be inserted until a click is heard.
marked “signal cable from POS Printer” at the rear of each cash drawer. The cable lengths for the two 8 pin plugs are different. Use the shorter one for the first cash drawer “CR1” and use the longer one for the second cash drawer “CR2” that will be controlled by the application software. Using this method, the TP6000 is capable of controlling two cash drawers independently through software command. WALL MOUNTING The main part in the wall mounting kit is a bracket as shown in the picture.
be either 360 mm or 380 mm depending on the adjusted position. When the main unit is tilted to near horizontal position, the total height required is 275 mm.
USING THE TOUCH POS APPLICATION ENVIRONMENT It is very important that you check the following operational guidelines: Ventilation This terminal must NOT be operated in an environment with restricted ventilation. The installation should be such that there is at least 25mm air clearance around any top or side ventilation holes. The installation must also be such that there is a free flow of air around the unit at ALL times.
Serial Port – COM1 CAUTION: The COM1 serial port should be occupied by either a suitable serial device or a COM1 terminator at all times (as supplied). Without this provision the cash drawer control ports will fail to work correctly. The recommended devices for COM1 are either an external customer display or a serial POS printer. When such devices are installed to the TP6000 series, please remove the COM1 terminator and store in a safe place for future use.
Ÿ When the external power fails and the TP6000 is working on the optional UPS battery power, the green LED flashes. Ÿ When the optional UPS battery is close to full discharge from supporting the TP6000 in the absence of the external power, the orange LED flashes rapidly. Ÿ When the TP6000 is turned off and the external power is not present, the LED is off. This system will not allow power up in the absence of an external power supply.
Software Support The TP6000 series provides a software power off command for application program maneuvers. The TP6000 also provides a specific means for the software to detect if the system is working on external or UPS battery power. Due to this feature, compatible software applications have the ability to change operating conditions when running on standard/backup power. The software programmer may take reference from the TP6000 technical manual to apply such features.
MAGNETIC STRIPE READER The magnetic stripe reader, if installed, will be mounted on the right edge of the TP6000 series. When reading an ISO standard magnetic card, please face the magnetic stripe toward the TP6000 series and slide the card downward through the slot.
TOUCH PANEL The touch panel in TP6000 series uses either a PS2 interface or an RS232 interfaced. When its driver is properly installed, this touch panel works exactly like a standard mouse. However, if the system is running under safe mode due to a previous improper shutdown or for any other reason, most drivers are disabled in this mode and the touch panel calibration may not coincide with the mouse pointer. It is recommended that a standard PS2 mouse or keyboard be used in this mode.
This program controls software gating of data read from each MSR track and the way that the data is sent from the reader to the system, including the coding method against language systems, data transmission speed, delivery and selection on the leading/ending code of each track. This program also controls the beep generated when the touch panel is touched, the detail in right button click emulation, and also provides touch panel recalibration.