USER MANUAL Power Must 400/600/800 LCD Uninterruptible Power System
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS –This manual contains important instructions for models Power Must 400/600/800 LCD that should be followed during installation and maintenance of the UPS and batteries. Safety – CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only factory service personnel may perform repairs. Internal battery voltage is 12Vdc.
Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Do not dispose of battery or batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries : 1) Remove watches, rings, or other metal objects from the hand.
System Description Front Panel— 1. LCD Back-Light 2. Power “ON/OFF” Switch Back Panel— 1. Communication Port(optional) 2. Modem/Phone Line Surge Protection 3. AC Output 4.
Installation and Operation Installing the UPS is as easy as following the steps shown. Be aware of the Power Switch must be kept in the “ON” position, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure. 1. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase. 2.
4. Computer Connection Connect one computer-related device into each of the power receptacles supplied on the back of the UPS (maximum of three devices). 5. Modem/Phoneline Connection Plug incoming internet line into the “In” socket at the back of the UPS. Use one more Internet line cable and plug one end of the Internet line cable to the “Out” socket at the back of the UPS. Plug the other end to the modem input socket as shown. Wa ll Outlet M odem/Fax/Phone 6.
. Turn On/Off To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again (When Switch ON The LED lighting.). 8. LCD Display Specification The LED will always turns on when UPS works, including in off charging mode and fault mode. When LCD start to work, it will display all information for 3s 1).When in normal mode, it will display as below. 2).When in AVR mode, it will display as below. And the mark flicker every 1second.
3).When in battery mode, it will display as below. And the mark will flicker every 1second. Note: If I/P-V<40V input voltage will display “000” 4).When in off charging mode, it will display as below. Note: the output voltage always is displayed as “000” in off charging mode. 5).When in fault mode, it will display as below. “FAULT” character and the reason of fault only. Note: the fault code will be showed in fault mode.
6).Load level definition: Load LEVEL Load bar Indication 0%~25% 25%~50% 50%~75% 75%~100% 7).Battery capacity definition: Battery LEVEL Battery bar Indication Battery voltage≤11V 11V≤Battery voltage≤11.5V 11.5V≤Battery voltage≤12.5V Battery voltage≥12.5V 8).When over load, the mark 9).When battery low, the mark will flicker every 1second. will flicker every 1second.
Software Installation -- WinPower -WinPower is a brand new UPS monitoring software, which provides user-friendly interface to monitor and control your UPS. This unique software provides safely auto shutdown for multi-computer systems while power failure. With this software, users can monitor and control any UPS on the same LAN no matter how far from the UPS Installation procedure: 1. Go to the website: http://www.ups-software-download.com/winpower.htm 2.
Trouble Shooting Use the table below to solve minor UPS installation or operation problems. If any abnormal situations occur that are not listed above,please call service people immediately. Symptom Possible Cause No LED display on 1. Missing battery. the front panel. 2. Battery defect. 3.When the Input cord isn’t electvified and Power switch is not pressed. Overload of the UPS. Alarm buzzer beeps continuously when AC supply is normal. When power 1. Overload of the UPS. failure, back-up time is shorten.
Specification MODEL CAPACITY INPUT VA/W 400 Power Must 600 800 400/240 600/360 800/480 Voltage Range 81-145VAC / Frequency Voltage 110 120VAC/220 230 240VAC Voltage Regulation OUTPUT +/- 10%(Battery Mode) Frequency 50Hz / 60Hz Frequency Regulation +/-1 Hz(Battery Mode) Output Waveform Battery Type BATTERY Back up Time Recharge Time TRANSFER TIME Typical INDICATOR LCD Display Models Modified Sine-wave 12V/4.