Dimensions Guide
4"
1"
½"
C
L
Sub Floor
1
/
8
" Gap
6 ½"
Square Opening
Finished Wall
Drywall
1
/
8
" Gap
39"
19½"
18½"
37"
Notice: Our continuous commitment to product improvement may result in changes to product specifications without notice.
Patents pending. Made and Printed in U.S.A.
E.L. Mustee & Sons, Inc. • 5431 West 164th Street • Brook Park, OH 44142 • Phone: 216.267.3100 • Fax: 216.267.9997
E-mail: info@mustee.com. • Web: www.mustee.com • Proudly made in the USA
CareGiver
®
3739 Transfer Shower Floor
Design features:
Produced from high-grade, reinforced, molded fiberglass for optimum
strength and impact resistance using matched metal molds under heat
and pressure.
Ideal for new or remodel projects…fits DURAWALL
®
Shower Walls (see
Accessories section) as well as ceramic tile or preformed wall kit.
Fits 39” wide by 37” deep alcove
Integrally molded-in drain with removable strainer and drain seal for
installation of 2” iron DWV (Sch. 40) PVC or ABS sanitary drain pipe.
1/2” High molded threshold to retain water.
Meets ADA requirements for a full 36” turning circle
Slip resistant Starburst
®
surface helps rapidly evacuate water to the drain
Center drain location
Available in white or bone
Smooth, colorfast semi-gloss finish, resists scuffs.
Mold and mildew-resistant…easy to clean
General: Furnish and install as shown on plans, CareGiver
®
Transfer Shower Floor Model 3739 as manufactured by E.L. Mustee & Sons, Inc. Shower
floor to be one-piece, molded fiberglass, using matched metal molds under extreme heat and pressure. Surface to be slip-resistant Starburst® design
that does not interfere with flow of water. Size: 37” x 39”. Shoulder will be not less than 3” high or less than 1” wide. Tiling flange will extend not less than
1” high to provide an integral water barrier. Threshold will be ½” high. Molded-in drain and drain seal for installation of 2” iron DWV (Sch. 40) PVC or ABS
sanitary drain pipe. Removable strainer. Shall meet ADA, ASTM D635, E84 and D635 and Code of Federal Regulation July 1, 1997 and July 1, 2007. Color
____ (White, Bone).
Code Accepted
Americans with Disabilities Act (ADA)
Code of Federal Regulations: July 1, 1997 and July 1, 2007 (ADA)
American Society of Testing & Materials (ASTM)-D635 Flammability,E84 Flame Spread, E165.75 Fire Retardancy
Specifications
SEE PAGES 2-4 FOR A LIST OF ACCESSORIES!
Model Description Drain Location Fits Alcove UPC
3739M White Center 37” x 39” 6 71031 00353 9
3739BN Bone Center 37” x 39” 6 71031 00354 6