Service manual
14
Light Bulb Replacement
Allow at least ve (5) minutes for light bulbs to cool before 
touching bulbs to avoid accidental burning of skin.
Light bulbs need to be replaced when you notice a dark 
section of the ame. There are two (2) bulbs under the log 
set which generate the ames and embers.
Disconnect power before attempting any maintenance or 
cleaning to reduce the risk of electric shock or damage to 
persons.
Helpful Hints
It is a good idea to replace all light bulbs at one time if they 
are close to the end of their rated life. Group replacement 
will reduce the number of times you need to open the unit to 
replace light bulbs. 
Light Bulb Requirements
Quantity of two (2) clear chandelier or candelabra bulbs with 
an E-12 (small) socket base, 60 Watt rating. 
Do not exceed 60 Watts per bulb
Replacement Procedure for:
DFI2309 & DFI2310 MODs ~ to C
1.  Remove the two (2) outer Phillips screws on the log grate 
at the front of the rebox as shown in Figure 11.
carefully bend the Flicker Rod enough to release the 
opposite end from the mounting bracket (Figure 12).
6.  Pull Flicker Rod off of the shaft of the Flicker Motor and 
set aside.
7.  Remove bulb(s) by turning counter-clockwise and replace.
8.  Push rubber grommet of Flicker Rod back onto shaft of 
Flicker Motor and carefully bend Flicker Rod so as to 
insert opposite end back into mounting bracket.
!
 NOTE: If Flicker Rod is bent out of alignment, carefully 
bend it back to become straight. If Flicker Rod is not 
properly aligned, it may cause noise during operation by 
rubbing against metal chassis.
9.  Follow steps 1 through 4 in reverse order to reassemble 
rebox.
Replacement Procedure for:
DFI2309 & DFI2310 MODs ~ to C
1.  Remove the four (4) Phillips screws on the log grate at the 
front of the rebox as shown in Figure 13.
Model / MOD Specic Procedures
Figure 11
2.  Pull the ame assembly drawer out approximately 1½ 
inches (4 cm), or until it stops.
3.  Carefully remove the Log Set from the rebox.
4.  Disconnect LED harness to Log Set (DFI2310 only). Set 
Log Set aside (Figure 12).
5.  Pull Flicker Rod to the far right, towards the Flicker Motor, 
Flame 
assembly drawer
Log Set
Screws to 
remove (2)
Figure 12
LED wire harness
Bulbs (2)
Flicker Rod
Figure 13
Bulbs (2)
LED wire 
harness
Screws to remove (4)
Log Set
Flicker Rod