Specifications
RoadRunner USERS GUIDE
71
If you have been given only one SPID
number, enter this number for the first ‘B’
channel only.
5ESS, Custom: If you service provider says you have
‘Custom ISDN’, you can have ‘point-to-
point’ or ‘point-to-multipoint’. In either
case, set the switch type to 5ESS Custom.
5ESS, National or Custom, version 5E9.1: 1 + area code + phone
number dialing is required for all calls,
including local.
DMS-100, National ISDN: SPID numbers are always used and begin
with the area code + 7 digit number. The
SPID number may end with ‘00’, ‘01’, ‘0100’
or other suffix. Enter the SPID number as
provided by your service provider, do not
put a ‘1’ in front of the SPID number. Select
NI1 as the switch type.
In any of the above cases, if SPID numbers are used, ID numbers are
also used. You must use a seven-digit ID number when using a
TA201/TA301.
Very early versions of the TA201/301 did not support 56 kb/s
operation. MUSICAM USA will be happy to upgrade any of these early
units if you require 56 kb/s connectivity.
Control Problems
Symptom Possible cause Solution
Keypad not
responding
1. Reset to factory defaults
Not responding to
remote terminal
control
—Improper cable.
—Incorrect port setting.
—Incorrect protocol mode.
1. Use standard RS232 cable
1. Check settings match terminal
or computer.
1. Insure RS232 protocol is ‘OFF’
for terminal control, ‘ON’ for
program control.
“Arguments Bad” —Incorrect number of 1. Check command syntax