CALIBRATION/SETUP
3. If a speaker or amplier is connected to the MS-8’s Channel 2, select
Channel 2 from the Channel Selection menu and repeat the procedure from
Step 2.
4. Repeat the procedure for each channel to which a speaker or amplier is
connected. Skip channels that are not connected to speakers or additional
ampliers. If you make a mistake, select the channel that you want to
correct, and then enter the correct selection. The MS-8 keeps track of the
number of channels that you have used and will not allow duplicate entries.
Check your entries carefully against the Conguration Chart you lled out on
page 11. Once you’re satised that everything is correct, select Done.
Output diagnostics
The MS-8 will then display the Output Diagnostics menu. We provide this
screen to help you conrm that your connections and channel assignments
are correct before you proceed to the next step.
Select any of the displayed speaker locations to hear pink noise through all of
the channels dedicated to that location. For example, if you’ve set up a three-
way front system, selecting Front Right will cause the MS-8 to send test noise
to the three channels you’ve designated as “Front Right” (hi, mid and lo).
Listen carefully as you move through the speaker locations. If you’ve made
a mistake (that is, if the noise is coming from a speaker other than the one
you’ve selected), you may be able to correct the mistake by reconnecting the
RCA or speaker-wire connectors on the MS-8’s output.
If you can’t correct the mistake by changing connections, correct your
Conguration Chart and hold the remote’s Back/Menu button to return to the
Xover Setup menu (see the If you make a mistake sidebar on page 27). You will
need to enter the all of the correct information again from the beginning of the
section.
Once you’ve determined that all connections and selections are correct, select
Done in the Output Diagnostics menu. The MS-8 will display the Speaker
Conf iguration Complete screen. When you’re ready to begin the acoustic
calibration procedure, select Continue.
ACOUSTIC CALIBRATION
The last step in setting up the MS-8 is making acoustic measurements
that will help the MS-8 optimize the sound at the driver’s seating position.
(You may also make acoustic measurements to optimize the sound at three
additional seats.) To get the best results for you and a single passenger, make
measurements in the driver’s and front passenger’s seats.
The MS-8 will display Error > Please Connect Microphone.
Connect the included binaural microphone headset to the MS-8’s Mic input
jack. (The MS-8 will not continue the calibration process until you connect
the microphone.) Carefully route the microphone’s cable to the driver’s seat,
leaving enough excess wire to accommodate the movement of your head. Sit
in the driver’s seat and place the headset mic on your head. Be sure that the
left and right microphones are on the correct ears!
Select Continue. The MS-8 will display Set Volume > -20dB.