SDS
1617632-Lithium-ion Battery Pack GMBA6200-25 62V 135Wh
_
_
Page 4 / 13
Note to physicians Product is a corrosive material. Use of gastric lavage or emesis is contraindicated.
Possible perforation of stomach or esophagus should be investigated. Do not give
chemical antidotes. Asphyxia from glottal edema may occur. Marked decrease in blood
pressure may occur with moist rales, frothy sputum, and high pulse pressure.
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing Media Use extinguishing measures that are appropriate to local circumstances and the
surrounding environment.
Large Fire CAUTION: Use of water spray when fighting fire may be inefficient.
Unsuitable extinguishing media
Do not scatter spilled material with high pressure water streams.
Specific hazards arising from the
chemical
The product causes burns of eyes, skin and mucous membranes. Thermal decomposition
can lead to release of irritating gases and vapors.
Hazardous Combustion Products Carbon oxides.
Explosion Data
Sensitivity to Mechanical Impact None.
Sensitivity to Static Discharge
None.
Special protective equipment for
fire-fighters
Firefighters should wear self-contained breathing apparatus and full firefighting turnout
gear. Use personal protection equipment.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Personal precautions Attention! Corrosive material. Avoid contact with skin, eyes or clothing. Ensure adequate
ventilation. Use personal protective equipment as required. Evacuate personnel to safe
areas. Keep people away from and upwind of spill/leak.
Other Information Refer to protective measures listed in Sections 7 and 8.
Methods and material for containment and cleaning up
Methods for containment Prevent further leakage or spillage if safe to do so.
Methods for cleaning up
Pick up and transfer to properly labeled containers.
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on safe handling In case of rupture: Handle in accordance with good industrial hygiene and safety practice.
Avoid contact with skin, eyes or clothing. Take off contaminated clothing and wash before
reuse. In case of insufficient ventilation, wear suitable respiratory equipment. Handle
product only in closed system or provide appropriate exhaust ventilation. Do not eat, drink
or smoke when using this product.