Full Product Manual
Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog
3-6
3
MURRAYLoad Centers
Load Centers
Circuit Breaker Enclosures & Small Load Centers
a 
 Hub provision only. Closure plate included. Panels 
through 225A require HS type hub.
b 
 Cover type is specified by character in 7th (usually last) 
position, as follows: 
   S = Surface 
F = Flush 
C = Combination Surface/Flush
 
 Dimensions shown are representative of outside box 
length, width & depth (±
1
⁄8”) and do not include allow-
ance for mounting bumps, endwalls, hubs or 
hardware protrusions. Allow approximately 1
1
⁄4” 
additional in length and width dimensions for surface 
or combination overhang. Consult factory for specific 
details if required.
 
 Use of 60A GFCI requires use of 75°C copper wire.
 
 Use neutral lug kit ECLK1 or ECLK2 as required.
 
 Panel includes factory-installed ground bar.
 
 Maximum breaker 100A.
 
Uses HA type hub. Closure plate included.
  For KO diagram, see Section 1 KO diagram for 
W0204ML1060
i 
Accepts type MQ breakers.
j 
 For service entrance use only 200A max. main breaker. 
Main breaker must be field added.
k 
 LW102NL shipped with ECHS125 hub instead of closure 
plate. LW204TL shipped with ECHS200 hub instead of 
closure plate.
l 
 Two MP115 and one MP230 provided.
m 
 50 Amp, 2-pole GFCI breaker installed.
n 
 60 Amp, 2-pole GFCI breaker installed.
 
 Uses ECHA hub type.
2-8 Circuit, 60-125 Amperes (no door)
Amps 
Max.
No. of 
Spaces
Max. 
Circuit
Indoor Type 1 
Catalog Number
b
Dimensions
Outdoor Type 3R
a
Catalog Number
Dimensions
Height Width Depth Height Width Depth
60 2 4
LC002GS
9
7
⁄8 5
1
⁄8 2
5
⁄8
LW002GR
8
1
⁄4 5
3
⁄8 4
1
⁄2
100 3 3
LP003CS
17
3
⁄5 7
1
⁄2 5
3
⁄5 — — — —
125 2 4
LC002HS
17
1
⁄8 7
1
⁄8 4
1
⁄4
LW002HR
8
1
⁄4 5
3
⁄8 4
1
⁄2
125 4 8
LC004NF
12
5
⁄8 6
5
⁄8 3
1
⁄2 — — — —
125 4 8
LC004NS
12
5
⁄8 6
5
⁄8 3
1
⁄2
LW004NR
12
1
⁄4 6
1
⁄8 4
1
⁄4
200 2 4
LC004VS
19
3
⁄4 8
1
⁄2 4
LW004VR
19
7
⁄8 8
3
⁄8 4
5
⁄8
225 2 4 — — — —
LW002QR
27 10
3
⁄8 5
5
⁄8
8-16 Circuit, 125 Amperes (with door)
125 8 16
LC008DF
14
3
⁄4 12
3
⁄8 3
7
⁄8 — — — —
125 8 16
LC008DS
14
3
⁄4 12
3
⁄8 3
7
⁄8
LW008NR
14
3
⁄4 12
1
⁄8 4
1
⁄8
125 8 16
LC008DFG
14
3
⁄4 12
3
⁄8 3
7
⁄8 — — — —
125 8 16
LC008DSG
14
3
⁄4 12
3
⁄8 3
7
⁄8 — — — —
Enclosed Breakers
100 2 4
LC100CS
17
1
⁄8 7
1
⁄8 4
1
⁄4
LW100CR
17
3
⁄8 7
3
⁄8 4
3
⁄8
200 2 4
LC200VS
19
3
⁄4 8
1
⁄2 4
LW200VR
19
7
⁄8 8
3
⁄8 4
5
⁄8
225 3 3 — — — —
LW903QR
27 10
3
⁄8 5
5
⁄8
  Amps  No. of  Max.  Indoor Type 1    Dimensions
  Max  Spaces  Circuits  Catalog No.  Height   Width  Depth  Main Breaker
  100  2  4  LW102NL
k
  12
1
⁄2  6  4
1
⁄4  MP2100  Factory
  200  4  8  LW204TL
k
  20  11
1
⁄8  4
3
⁄4  MPD2200R  Factory
  200  4  8  LW004TR
j
  20  11
1
⁄8  4
3
⁄4  MD-T(R), MD-HT(R)  Field
  200  8  16  LW0816L1200TR
j
  29  14
1
⁄4  4
1
⁄2  MBK150M or MBK200M  Field
Outdoor
a
 Trailer Panels - 120/240V AC 208Y/120V AC
Spa Panels
Ampere 
Rating
No. of 
Spaces
Max. 
Circuits 
Catalog 
Number
Dimensions
Height Width Depth
125 2 4
LW004NRSPA50
m
12
1
⁄4 6
1
⁄8 4
1
⁄4
125 2 4
LW004NRSPA60
n
12
1
⁄4 6
1
⁄8 4
1
⁄4
Renovation Panels - 3 Wire 120/240V AC
200 24 40
LC024PFR
30 14 3
7
⁄8
100 10 20
LC110DFCGP
l
14
3
⁄4 12
3
⁄8 3
1
⁄8
n Ideal for Narrow stud applications
n Eliminated “notching” needed for standard Load Centers
n Outdoor Load Center with factory installed Ground Fault 
Breaker
n Two extra circuits
n Factory installed feed-through lugs
n Main Breaker or Main Lug panels available
Siemens / Speedfax  Previous folio: Murray  SS 2/14/11
Product Category RESI
LC002GS LC004NS