Full Product Manual
Siemens Industry, Inc. SPEEDFAX™ 2017 Product Catalog
3-4
3
MURRAYLoad Centers
a 
100-225A only.
b
 This information is based on use of 10,000 AIC rated 
branch circuit breakers in load center (MP-T, MH-T, 
MP-GT, MG). Most series ratings exclude MH-T 
above 40 Amp. Consult device wiring diagram for spe-
cific data.
 
 Remote Only
 Types MQH & MQL may be mounted internal in 150-225 
amp 3
Ø
 main breaker load centers.
 
 Dimensions shown are representative of outside box 
length, width & depth (±
1
⁄8”) and do not include allowance 
for mounting bumps, endwalls, hubs or hardware protru-
sions. Allow approximately 1
1
⁄4” additional in length and 
width dimensions for surface or combination overhang. 
Consult factory for specific details if required.
 
Hub provision only. Closure plate included. Panels 
through 225A require HS type hub; panels over 225A 
require HV type hub.
 
 Standard package quantity equal to 1.
 
 Copper bus load centers are recommended for those 
applications where the environment may be severe 
(ie farm and coastal areas).
Rock Solid Load Centers
Main Breaker, 1Ø, 22,000 AIC
a
Load Center Short Circuit Current Rating
Copper Bus
 Amps  No. of  Max.  Indoor Type 1
    Dimensions
  Max.  Spaces  Circuit  Catalog Number  Height  Width  Depth
  100  20  40  LC2040B1100CU  24  14
3
⁄8  4
  200  20  40  LC2040B1200CU  30  14
3
⁄8  4
  200  30  40  LC3040B1200CU  36  14
3
⁄8  4
  200  40  40  LC4040B1200CU  39  14
3
⁄8  4
Load Center Short Circuit Current Rating
  Load Center    Internal or Remote
  Short Circuit  Load Center  Main or Feeder
  Current Rating
b
  Main Rating  Circuit Breaker Type
  10,000 AIC  Any  Any
  22,000 AIC  100/125A  MP-HT, MQH
    150/200/225A  MD-H, MQH
b
, MPP-HT
  42,000 AIC  100/125A  MQL
    150/200/225A  MQL
b
  65,000 AIC  100/125A  MP-MT, MPP-MT
    150/200/225A  MPP-MT
  100,000 AIC  100/125A  100A, 300V AC, Class “T” Fuse
  100,000 AIC  150/200/225A  200A, 300V AC, Class “T” Fuse
LC2040B1200
Load centers on this page through 200 amp feature a new split neutral with 
one bonded and one insulated bar. For service entrance applications, install 
bonding strap, and use both bars for neutral and ground conductors. For non 
service entrance applications, do not install bonding strap and use insulated 
bar for neutral conductors and bonded bar for ground conductors.
Siemens / Speedfax  Previous folio: Murray  SS 2/14/11
12-42 Circuit, 100-200 Amperes
Amps
Max.
No. of
Spaces
Max.
Circuit
Catalog Number Dimensions
Outdoor Type 3R
Dimensions
Indoor Type 1
Height Width Depth Catalog Number Height Width Depth
100 12 24
LC1224B1100
18 14
3
⁄8 4
LW1224B1100
23 14
1
⁄4 4
1
⁄2
100 16 32 — — — —
LW1632B1100
23 14
1
⁄4 4
1
⁄2
100 20 40
LC2040B1100
24 14
3
⁄8 4 — — — —
100 24 40
LC2440B1100
24 14
3
⁄8 4 — — — —
100 30 40
LC3040B1100
30 14
3
⁄8 4 — — — —
150 16 32
LC1632B1150
24 14
3
⁄8 4 — — — —
150 20 40
LC2040B1150
30 14
3
⁄8 4
LW2040B1150
29 14
1
⁄4 4
1
⁄2
150 24 40
LC2440B1150
30 14
3
⁄8 4 — — — —
150 30 40
LC3040B1150
36 14
3
⁄8 4 — — — —
200 12 24 — — — —
LW1224B1200
29 14
1
⁄4 4
1
⁄2
200 16 32
LC1632B1200
30 14
3
⁄8 4 — — — —
200 20 40
LC2040B1200
30 14
3
⁄8 4
LW2040B1200
29 14
1
⁄4 4
1
⁄2
200 24 40
LC2440B1200
30 14
3
⁄8 4 — — — —
200 30 40
LC3040B1200
36 14
3
⁄8 4
LW3040B1200
38 14
1
⁄4 4
1
⁄2
200 40 40
LC4040B1200
39 14
3
⁄8 4
LW4040B1200
38 14
1
⁄4 4
1
⁄2
200 30 54
LC3054B1200
36 14
3
⁄8 4 — — — —
200 40 40
LC4040B1200
39 14
3
⁄8 4 — — — —
200 40 60
LC4060B1200
40
1
⁄2 15
7
⁄8 5 — — — —
Product Category RESI
Murray load centers have UL recognized 
short circuit current ratings up to 100,000 
Amps, when used with appropriate main 
or feeder (remote or internal) overcurrent 
devices. Load center ratings are shown 
below. For load center applications 
with residential or commercial metering 
equipment, refer to the appropriate 
catalog section.
1
Ø
, main breaker load centers are 
Underwriter’s Laboratories Listed 
for use with 60/75°C conductors and 
accept Murray branch circuit breakers 
which are also UL Listed for use 
with 60/75°C conductors. Type 3R 
load centers are furnished with a hub 