Specifications
Engine Protection 59
Order by Phone 1-800-667-8001
Order On-Line www.farmtronics.com
Mechanical Temperature SWICHGAGE
®
|
3 Combination Indicating Gauge and Limit Switch
3 Critical Temperature Limit Switch is Visible and Adjustable
3 Switch Can Activate Alarms and/or Shutdown Equipment
3 Contact Grounds Through Case
3 2 1/2” dial, white on black, dual scale not lit
3 2 1/2” dial, black on white, dual scale with light
Order No. Mfg. PN Description Price
20T Series Temperature SWICHGAGE
®
This diaphragm-actuated, temperature indicating SWICHGAGE
®
has built-in electrical
switches for tripping alarms and/or shutdown devices. The SWICHGAGE
®
pointer acts
as a temperature indicator and has one switch pole which completes a circuit when it
touches the adjustable limit contact. Available in 250 or 320
o
F and 4’-16’ capillary lengths.
Higher temperature ranges are for use on air-cooled engines where the probe is inserted
into the oil pan. English and metric scales. 2 ½” dial, 2 1/6” mounting hole, not lit. The
20T-IPI is the same except has a light for night use. Specify 12 or 24V.
E69710 20T-250-4 250
o
F with 4’ capillary $83.95
E69720 20T-250-6 250
o
F with 6’ capillary $89.95
E69730 20T-250-8 250
o
F with 8’ capillary $91.95
E69740 20T-250-10 250
o
F with 10’ capillary $94.95
E69760 20T-250-16 250
o
F with 16’ capillary $95.95
E69810 20T-320-6 320
o
F with 6’ capillary $83.95
E69800 20T-320-16 320
o
F with 16’ capillary $95.95
E69821 20T-IPI-6 250
o
F 12V with 6’ capillary and light $107.95
E69822 20T-IP2-6 250
o
F 24V with 6’ capillary and light $227.95
E69831 20T-IP1-8 250
o
F 12V with 8’ capillary and light $113.95
E69832 20T-IP2-8 250
o
F 24V with 8’ capillary and light $239.95
20TH Cylinder Head Temperature SWICHGAGE
®
Temperature for air cooled engines can be measured in the cylinder head or in the
lubricating oil. Oil temperature will give a more uniform reading than cylinder head since
the oil circulates throughout the engine. Generally the cylinder head must already have
a hole drilled and tapped for insertion (10 mm x 1.5 thread) of the temperature sensing
probe. 2 ½” dial, 2 1/6” mounting hole, not lit, 4’ capillary.
E69870 20 TH-320-4-M10 Cylinder Head Temperature SWICHGAGE
®
$107.95
20T-250
20T-320
20 TH-320
CAUTION: Do not cut a capillary.
I t contains chemicals or solvents
which may be hazardous under
certain circumstances.
Custom Engine Panels
Industrial
l
Agricultural
l
Marine Engines
Assemblies available or can be designed for most engine applications.
Whether shutdown occurs by control of ignition or diesel fuel valve,
FARMTRONICS can create custom panels with other options such as:
l Time delay and alarm before shutdown l Engine rpm
l Turbo cool down before shutdown l Coolant Pressure
l Control and instrument panels l Switch Panels
l Power Distribution Load Centres l Electronics
l Panel Lettering
20T-IP2-6