HelmView™ Model HV1000 Operations Manual 00-02-0604 02-01-07 Section 78
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. The latest version of this manual can be found at www.fwmurphy.com. Warranty - A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm Please read the following information before installing.
Table of Contents Product Information................................................................................................................ 1 Display Features ..........................................................................................................1 Mounting Options .........................................................................................................2 HV1000 Navigation..............................................................................................
(THIS PAGE INTENTIONALLY LEFT BLANK)
Product Information The HelmView™ Model HV1000 display is designed for instrumentation and control on electronically controlled engines communicating using SAE J1939 and NMEA 2000. The HV1000 display is a multifunction tool that enables equipment operators to view many different engine or transmission parameters and service codes, and can support up to four engines simultaneously. Display Features Fault Lights These indicators, located in the top two corners of the unit, will light up when a fault occurs.
Mounting Options Two mounting options are provided for the HV1000 display. The in-dash mounting option will require a hole to be cut for insertion of the display. A template is provided with the depth and dimensions of the display for easy installation. The gimbal-mount method enables the display to be installed on top of the dash. The gimbal design allows rotating and tilting the unit for the best display position for the operator’s viewing.
HV1000 Navigation Navigating the HV1000 display is accomplished using two sets of buttons - one fixed and one virtual - to access menus, pop-ups, and make selections from available options. Each time a button is pressed, confirmation of the button press is given by the amber light at the lower left corner of the display. Fixed Buttons The fixed buttons run across the bottom of the display for Menu, Previous, Next, and Select options.
Virtual Buttons A column of vertical buttons located to the right of the display are virtual buttons. They will change according to the options available for the screen being displayed.
Menu The Menu can be accessed at any time, from any screen being displayed, by pressing the Menu button. The Menu button symbol is always located in the first position of the fixed buttons. Popup The Popup button utilizes the virtual keys to the right of the display to provide shortcuts for navigation and display options.
Setting Up your HV1000 Display for the First Time The guidelines presented below are intended for setting up the HV1000 display for the first time. Once the configuration is set up, there is no need to revisit or change any of the settings. NOTE: If you require assistance during the set up process, contact FW Murphy customer support at (918) 317-4100. 1. At the main menu, press the Next button to move the highlight bar through the options until ‘Utilities’ is highlighted. 2. Press Select.
3. From the ‘Utilities’ sub-menu, select ‘System Settings’. The following screen is displayed. 4. With the cursor highlighting the ‘Wiring Config’ field, press the Scroll Up or Scroll Down virtual buttons (located to the right of the display), to scroll through the list of options.
Engine Type Crusader Single Engine Configuration Twin Engine ** Configuration (A) Single Harness Plug A-Port, Stbd Volvo non-EVC Gas (C) Dual Harness Plug A&B-Port, Stbd (A) Single Harness Plug A-Port, Stbd Or (B) Single Harness Plug A-Stbd, Port (C) Dual Harness Plug A&B-Port, Stbd Or (D) Dual Harness Plug A&B-Stbd, Port (E) Plug D-Port, Stbd Or (F) Plug D-Stbd, Port (C) Dual Harness Plug A&B-Port, Stbd Or (D) Dual Harness Plug A&B-Stbd, Port (C) Dual Harness Plug A&B-Port, Stbd Or (D) Dual Harness P
7. When the correct setting for ‘Plug Address’ is displayed, press the Save button. The ‘Utilities’ sub-menu is displayed. Once the ‘System Settings’ have been configured, you may want to set up your display options and favorites. For information on this process, refer to the “User Setting” section located in this manual.
Product Features Power Up The HelmView display is most frequently installed with power connected to the ignition. When the ignition is turned on, the HelmView display powers up and the engine health statistics can be viewed via preset gauges. To see more gauge screens, press the Next or Previous buttons. Main Menu The main menu is activated at any time by pressing the Menu key on the display.
Gauge Display The Gauge Display screen consists of several predefined layouts that contain combinations of analog gauges, curved bar (half-moon) gauges, straight bar gauges, or digital (text) readouts. These screens are displayed upon startup. You can scroll through the various gauge screens by pressing the Next and Previous buttons. This can be repeated until all screens have been viewed. The currently displayed screen will stay active until another button is pressed.
Screen Names - When selected, a small window appears at the top right of the display. This window contains the names of each of the screens that are currently “Turned ON”. Using the Previous and Next buttons allows you to scroll through and display the various gauge configurations. NOTE: For instructions on how to turn screens ON or OFF, refer to the “User Settings” section of this manual. GPS Display - When selected, a GPS map is displayed.
Day Night - Allows you to toggle the display screen between Day View and Night View. NOTE: This feature can also be changed in the “User Settings” section of this manual. Home - This one-touch navigation feature allows a pre-defined Home screen to be accessed from the available Gauge Display screens. Once selected, the Home screen will be displayed anytime the Home button is pressed. NOTE: For instructions on how to setup the Home screen, refer to the “User Settings” section of this manual.
GPS Display GPS Display is accessed by selecting it from the main menu or the Gauge Display popup. The GPS feature displays the map data and up to 3 configurable gauges. Latitude and Longitude coordinates are also listed, as well as course and speed. You can navigate the GPS map by pressing the Up, Down, Left, and Right buttons to move the cross-hairs on the map. You can also press the Zoom In button for more detail or the Zoom Out button for a larger view.
NOTE: In order for this information to be available on the HelmView, a GPS antenna (P/N 78-70-0250) that is NMEA2000 compatible must be installed. This NMEA2000 device (along with any others) should be networked using valid NMEA2000 cabling and terminating resistors (Installation Kit P/N 78-70-0261). The NMEA2000 cabling should ALWAYS be plugged into Plug D (Port D) on the back of the display. See the “HelmView Installation Manual” for further information.
Engine Diagnostics When choosing this selection, the display will query the engine(s) ECU and provide feedback on any diagnostic codes that have been activated and stored in the ECU for service needs. The Engine Diagnostics option displays faults based on engine or auxiliary source. A description of the fault as well as the suggested action for correction is provided for each fault occurrence.
The following is a list of field definitions contained on the ENGINE DIAGNOSTICS screen: • Source – identifies the component having the fault; engine 1, 2, or auxiliary. • Status – indicates whether the fault has been corrected. • SPM –"Suspect Parameter Number" - fault code If not translated into text by the HV1000 display, see the engine manufacturer's literature for the definition of the SPN number. • FMI – “Failure Mode Indicator” - fault code The FMI is defined by SAE J1939.
Fault Code Pop-ups A fault condition will trigger a pop-up dialog box on the screen describing the nature of the fault. Corresponding red or amber fault lights on the corners of the unit are also activated to indicate the severity of the fault. The following screens are examples of warning and shutdown fault code pop-ups. Warning Shutdown How to Hide/Show Faults To hide the fault code pop-up being displayed on the screen, press the virtual button on the right next to the “Hide” icon.
User Settings User Settings provides options to specify viewing preferences for the HV1000 DISPLAY. Pressing Prev and Next navigates through the options, and Up and Down scrolls through the selections for each option. Ambient Light Night and Day options are provided for ambient lighting. The screens below illustrate these options. When the ambient lighting settings are changed in User Settings, the power-on default is changed.
Brightness You can set the brightness control by using the UP and DOWN virtual buttons to change the settings in 5% increments until the desired brightness is achieved. Units Select how units are displayed by using the UP and DOWN virtual buttons to select: • US Std (US Standard) • Metric KPa • Metric Bar • English Imp (English Imperial) • Nautical Language This option allows you to select the language that will be displayed on the HelmView.
Utilities Utilities allow you to reset external gauges and configure wiring and communication settings. It is typically only accessed when the unit is first installed in order to configure the unit. The following sub-menu is displayed when Utilities is selected. System Settings The System Settings screen displays the current software version loaded on the HV1000 DISPLAY. You can set individual settings for the available options, or choose to select “Restore Defaults” for the factory settings.
The Prev and Next buttons allow you to move from field to field. While the cursor is highlighting a field, the Scroll Up and Scroll Down buttons display available options. Once all the options have been selected, press Save. NOTE: For guidelines to configure your HV1000 display, refer to the “Setting Up your HV1000 Display for the First Time” section of this manual. Trip Reset This option resets the trip computer and fuel economy calculations.
GPS Utilities When using a GPS device, GPS Utilities will allow you to configure and monitor satellite tracking data. The following sub-menu is displayed when GPS Utilities is selected. Satellite Status This feature displays a graphic indicating the satellites currently visible in orbit and the signal strength of each satellite.
Track and Position Setup This feature allows you to define the amount of detail to display for the longitude and latitude information on the GPS map. Pressing the Delete Track button will delete the current tracking information. Restore Defaults will reset the longitude and latitude to the factory default setting.
Chart and Time Setup This menu option allows you to set up viewing options for the GPS Display. Chart Setup Parameters – use the Check/Uncheck button to select the information you want displayed on the GPS screen. Splitscreen Gauge Selection – allows you to custom configure the type of gauges you want to display in split screen mode. Time Setup Parameters – is used to select correct time zone and clock mode for either 12hour or 24-hour time formats.
Waypoint Manager Waypoints allow you to mark specific locations by latitude and longitude. Once the waypoints are established, the Waypoint Manager allows you to associate an icon with them for identification. You can delete a single waypoint by using the Delete button, or all of them at once with Delete All. Pressing the Go to WPT button displays the GPS screen containing the currently highlighted waypoint. Waypoint List – displays a list of the waypoints that have been set.
Reprogramming the HV1000 Display The SD card slot on the front of the unit is used for reprogramming the unit. It is also used for installing the Navionics maps that are retrieved by the GPS Maps package. If you have been asked to create the card to reprogram the unit, you should: 1. Insert card into reader/writer. 2. Unzip the file provided into a directory on the PC. 3. Format the card to erase all current files residing on the card. 4. Copy all of the files in the directory to the SD card.
Specifications Electrical Display Resolution Orientation Backlighting Processor Flash Memory RAM EEPROM Operating Voltage Power Consumption CAN RS-485 Protocols Connection Keyboard 6.
Environmental Operating Temperature Storage Temperature Protection Emissions Immunity -20º C to +85º C (-40º C with optional heater) -40º C to +85º C IP68 IEC 60945, 95/54/EC SAE J1113, ISO 11452 NMEA 2000 Parameter Group Numbers (PGNs)* 127245 127250 127488 127489 127493 127505 127508 128259 128267 129025 129026 130310 130576 *Partial List Section 78 02-01-07 Rudder Vessel Heading Engine Parameters, Rapid Update Engine Parameters, Dynamic Transmission Parameters, Dynamic Fluid Levels Battery Status Spe
J1939 Parameter Group Numbers (PGNs)* 61442 61443 61444 61445 65164 65213 65243 65248 65253 65257 65262 65263 65265 65266 65269 65270 65271 65272 *Partial List Section 78 02-01-07 ETC1 – Electronic Transmission Controller 1 EEC2 – Electronic Engine Controller 2 EEC1 – Electronic Engine Controller 1 ETC2 – Electronic Transmission Controller 2 AAI – Auxiliary Analog Information FD – Fan Drive EFL/P2 – Engine Fuel Level/Pressure 2 VD – Vehicle Distance HOURS – Total Engine Hours LFC – Liquid Fuel Consumption
MURPHY, the Murphy logo, HelmView™ and HV1000™ are registered and/or common law trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyright protected by Murphy Industries, Inc., with all rights reserved. (c) 2007 Murphy Industries, Inc. Other third party product or trade names referenced herein are the property of their respective owners and are used for identification purposes only.