Specifications

Section 20 00-02-2003
06-21-10 - 12 -
6. Reconnect the 3-pin connector by pushing it onto the header until it snaps into place.
7. Thread the conduit connectors into the EVS EX housing until snug.
8. Screw in the top cover until snug.
External Charge Accelerometer Wiring
1. Remove the EVS EX top cover.
2. Connect the Power and Relay wires per instructions above.
3. Feed the Coaxial cable that leads from the Charge accelerometer through the bottom
¾” NPT opening.
4. You will have to wrap the coaxial cable around the inside diameter of the EVS EX in
order to thread the cable connector onto the header. The internal surfaces of the EVS
switch enclosure are smooth so there is no fear that the coaxial cable can be damaged.
5. Screw the coaxial connector onto the header.
6. Thread the conduit connectors into the EVS EX housing until snug.
7. Screw in the top cover until snug.
PHASE OUT / DISCONTINUED
Check Availability