General Information
Introduction
As part of the MurphyLink® family, the CANdrive offers a cost effective instrument solution
for modern electronic engines. CANdrive acts as an interface between ECU CANbus/J1939
transmitted data and standard electric indicating gages. CANdrive and electric gages are an
alternative solution to retrofitting of engine senders, magnetic pickups and associated wiring.
CANdrive has dedicated outputs for a tachometer, oil pressure, and coolant temperature
electric gages. Configurable switch settings allow for selectivity between 12 or 24 VDC
systems, and for all gage outputs to be selected for Murphy, VDO, or Datcon.
CANdrive is packaged in a compact, surface-mounted case with epoxy encapsulation for
maximum durability and environmental sealing. Electrical connection is through a 12-way
automotive-type connector.
Standard Model Options
Stock Code Model / Description
78-70-0363
CDV100F, CAN drive J1939 to electric gage interface. 1 x CAN
status LED, connector forward
78-70-0364
CDV300R, CANdrive J1939 to electric gage interface. 8 x
status/fault LEDs, connector rearward. Model CDVG sealing
gasket included.
78-00-0437
CDV-PW-30, CANdrive power and CAN harness. Length: 30 in.
(0.762m). Included with CDV100F and CDV300R