Operating instructions
CANdrive installation and operation 00-02-0618 revision G 2013-10-22 p2/4
General Information (cont.)
CDV100F
front view
CDV300R
front view
Rear view System connection
Panel Installation
CANdrive modules are surface-mounted with 4 x no.4 screws, fixing centre dimensions as
shown. Select screw length according to panel thickness, ensuring a maximum of 13mm
(½ inch) screw depth into the CANdrive fixing holes.
Model CDV100F, with forward facing connector, is designed for surface mounting inside
an enclosed panel. Model CDV300F, with 8 LED indicators and rearward facing connector,
is designed for front-of-panel mounting: this module requires an additional 60 x 40mm
(2.4 x 1.6 in.) panel cut-out for rear access to connector and switches. A CDV300F with
optional gasket CDVG (fitted into a well behind the case rim) provides IP65 front-of-panel
environmental sealing.
Before installing, ensure that the final mounting location meets operating temperature and
environmental sealing requirements, and allows access for:
a) connection of the wiring harness
b)
configuration of DIP switches S1 to S5 (location as shown above right). Alternatively,
set these switches before panel fixing – see Configuration section below for full details.
Dimensions
mm (in.)
Configuration
DIP switches S1 to S5 allow OEM- or user-configuration of
CANdrive operating options. Switch S6 is not used. CANdrive
is supplied with all switches in the ON (up) position.
Switch settings must be made as appropriate, according to
the configuration table right. Adjustment of the switch
positions must be made while CANdrive is powered down.
Switch
position
on (up)
off (down)
Options:
S1 S2 S3 S4 S5
Murphy EG(S) temp. and pressure gauges
Datcon temp. and 0 – 7 bar pressure gauges
atcon temp. and 0 – 10 bar pressure gauges
VDO temp. and 0 – 5 bar pressure gauges
VDO temp. and 0 – 10 bar pressure gauges
CAN 120 Ohm terminating resistor in circuit
CAN 120 Ohm terminating resistor removed
12V DC power supply
24V DC power supply
Pressure gauge compatibility table: pressure versus approximate equivalent sender resistance (Ohms)
Pressure psi 0 10 20 30 40 50 60 70 80 90 100 110 1
0 130 140
bar 0 0.7 1.4 2.1 2.8 3.4 4.1 4.8 5.5 6.2 6.9 7.6 8.3 9.0 9.7
Murphy ES series 240 205 171 143 123 103 88 74 60 47 33
Datcon 0 – 7 bar 240 195 160 140 115 100 82 68 55 43 35
Datcon 0 – 10 bar 240 215 190 168 150 135 118 107 97 87 77 67 58 50 42
VDO 0 – 5 bar 10 38 61 85 110 130 155 180
VDO 0 –10 bar 15 30 45 60 70 81 92 103 114 125 136 148 160 170 182
Temperature gauge compatibility table: temperature versus approximate equivalent sender resistance (Ohms)
Temperature °C 40 50 60 70 80 90 100 110 120 130 140
°F 104 122 140 158 176 194 212 230 248 266 284
Murphy ES series 1029 680 460 321 227 164 120 89 74 52 40
Datcon 360 160 80 50 38
VDO 282.4 190.0 134.0 95.2 69.1 51.2 38.5 29.4 22.7 18.0 14.5