Specifications

3-10
Machine Parameter C:0
Switch
Initial
Setting
Adjust Usage/Comments
70
60
50
40
30
20
10
00
Mirror carriage standby
position adjustment
Adjusts the number of the
steps from the home sensor
of the mirror carriage OFF
to the standby position.
1 step = 0.140793616 mm
Note:
These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Switch 76543210 Settings
63 steps 00111111 +8.87 mm
:
60 steps 00111100 +8.45 mm
:
50 steps 00110010 +7.04 mm
:
40 steps 00101000 +5.63 mm
:
30 steps 00011110 +4.22 mm
:
20 steps 00010100 +2.82 mm
:
10 steps 00001010 +1.41 mm
:
3 steps 00000011 +0.42 mm
2 steps 00000010 +0.28 mm
1 step 00000001 +0.14 mm
00000000 36 mm Initial setting
When Switch 7 is “1”, it means “ - ”. For example,
“10000001” means “-0.17 mm”.
Machine Parameter C:1 C:9 --- Factory use only
Machine Parameter D:0
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0
Scanning contrast level
adjustment in normal
resolution.
Switch 76543210
01111111 Darkest setting
:
00001000
:
00000000 Initial setting
:
10001000
:
11111111 Lightest setting