3-9
Machine Parameter B:8
Switch
Initial
Setting
Adjust Usage/Comments
70
60
50
40
30
20
10
00
Leading edge document
margin adjustment
(FBS)
Adjusts the number of the
steps from the home sensor
of the mirror carriage ON
to the start of the scanning
position.
1 step = 0.140793616 mm
Note:
These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Switch 76543210 Settings
31 steps 00011111 +4.36 mm
:
16 steps 00010000 +2.25 mm
:
8 steps 00001000 +1.13 mm
:
4 steps 00000100 +0.56 mm
:
2 step 00000010 +0.28 mm
:
1 step 00000001 +0.14 mm
00000000 5 mm Initial setting
-1 step 10000001 -0.14 mm
:
-2 steps 10000010 -0.28 mm
:
-4 steps 10000100 -0.56 mm
:
-8 steps 10001000 -1.13 mm
:
-16 steps 10010000 -2.25 mm
:
-31 steps 10011111 -4.36 mm
Machine Parameter B:9 --- Factory use only