Specifications
3-7
Machine Parameter B:4
Switch
Initial
Setting
Adjust Usage/Comments
70
60
50
40
30
20
10
00
Adjusts the number of the
steps from DS2 OFF to the
start of the scanning position.
(ADF)
1 step = 1 / 300 inches × 2
(0.084666 mm × 2)
Note:
These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Switch 76543210 Settings
63 steps 00111111 +10.67 mm
:
60 steps 00111100 +10.16 mm
:
50 steps 00110010 +8.47 mm
:
40 steps 00101000 +6.77 mm
:
30 steps 00011110 +5.08 mm
:
20 steps 00010100 +3.39 mm
:
10 steps 00001010 +1.69 mm
:
3steps 00000011 +0.51 mm
2steps 00000010 +0.34 mm
1 step 00000001 +0.17 mm
00000000 31 mm Initial setting
When Switch 7 is “1”, it means “ - ”. For example,
“10000001” means “-0.17 mm”.
Machine Parameter B:5
Switch
Initial
Setting
Adjust Usage/Comments
70
60
50
40
30
21
10
01
Leading edge document
margin adjustment
(FBS)
Adjusts the leading edge
margin from standby
position to the start of the
scanning position.
1 step = 5 / 600 dpi
(0.2116 mm)
Note:
These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Switch 76543210 Settings
25 steps 00011001 +5.29 mm
:
00100000 +6.77 mm
:
00010000 +3.39 mm
:
00001000 +1.69 mm
:
00000101 +1.06 mm Initial setting
:
00000000 0 mm Standard
:
10001000 -1.69 mm
:
10010000 -3.39 mm
:
-25 steps 10011001 -5.29 mm