Specifications
3-6
Machine Parameter B:2
Switch
Initial
Setting
Adjust Usage/Comments
70
60
50
40
30
21
10
00
Adjustment of the scanning
stretching and squeezing for
ADF.
(Vertical)
The plus setting stretch the
image data and the minus
setting squeeze it.
Each setting changes by
0.1%
Switch 76543210 Settings
00001111 +1.5 %
:
00001000 +0.8 %
:
00000100 +0.4 % Initial setting
:
00000010 +0.2 %
00000010 +0.1 %
00000000 0 % Standard
00000010 -0.1 %
00000010 -0.2 %
:
10000100 -0.4 %
:
10001000 -0.8 %
:
10001111 -1.5 %
Machine Parameter B:3
Switch
Initial
Setting
Adjust Usage/Comments
70
60
50
40
30
20
10
00
Adjusts the number of the
steps from DS2 ON to the
start of the scanning position.
(ADF)
1 step = 1 / 300 inches × 2
(0.084666 mm × 2)
Note:
These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Switch 76543210 Settings
63 steps 00111111 +10.67 mm
:
60 steps 00111100 +10.16 mm
:
50 steps 00110010 +8.47 mm
:
40 steps 00101000 +6.77 mm
:
30 steps 00011110 +5.08 mm
:
20 steps 00010100 +3.39 mm
:
10 steps 00001010 +1.69 mm
:
3steps 00000011 +0.51 mm
2steps 00000010 +0.34 mm
1 step 00000001 +0.17 mm
00000000 31 mm Initial setting
When Switch 7 is “1”, it means “ - ”. For example,
“10000001” means “-0.17 mm”.