Specifications
3-86
Memory Switch C:1 - Reception
Switch
Initial
Setting
Adjust
Usage/Comments
7
0
Factory use only
6
0
Factory use only
5
0
Received document length
limit
0: No limit
1: 3 m (9.8 feet)
Set the limit of received document length.
4
0
T1 timer
0: 35 sec
1: 20 sec
Adjusts the T1 time-out. After the machine dials the
remote machine’s phone number, it begins sending
CNG and waits this amount of time before
disconnecting the line.
3
1
Print image data when post
message is not received after
receiving RTC signal
0: No
1: Yes
If the received document includes the RTC, the
machine prints the data even though the following
protocol is not succeeded.
2
0
Disable ITU-T superfine
reception
0: Yes
1: No
Set to “1” if a compatibility error occurs because the
transmitting machine does not understand the
extended frame for ITU-T superfine resolution.
(Note: Setting this switch to “1” will disable superfine
mode.)
1
0
G3 echo receive
Adjusts the delay between detection of training/TCF and sending of CFR.
0
1
100 ms 500 ms 800 ms 1200 ms
Switch 1 0 0 1 1
Switch 0 0 1 0 1
Memory Switch C:2 ∼ C:9 --- Factory use only