7
0
Data signaling rate (DCS)
0: V.17
1: V.33
Determines communication protocol.
6
0
Forced received print when
transmitting from memory
0: No
1: Yes
Will force a remote Muratec machine with memory
receive capabilities to print directly. This switch will
prevent a memory overflow error at the remote unit.
5
0
Changing the date format of
the transmitted TTI
0: No
1: Yes
When set to “1”, the machine changes the date
format of the transmitted TTI from MM:DD:YY, or
vice versa.
4
1
TTI transmit
0: No
1: Yes
When set at “0”, transmission of the TTI is disabled.
(Note: Turning TTI transmission off may violate
local or federal regulations.)
3
0
ECM response time
0: 3 sec
1: 4.8 sec
The time limit to receive the response signal for the
ECM post message.
2
0
ECM error retransmit time
0: 200 ms
1: 400 ms
The time limit before the ECM error is
retransmitted.
1
0
Interval between DIS and DCS
0
0
0 ms 500 ms 1000 ms 1500 ms
Switch 1 0 0 1 1
Switch 0 0 1 0 1
Memory Switch B:3 - Transmission
Switch
Initial
Setting
Adjust
Usage/Comments
7 0 ANSam detection
0: Yes
1: No
During the V8 handshake, if some noise disturbs
the handshake and an error occurs, set to “1”.
6 0 V.34 transmission
0: Yes
1: No
Individual setting for V.34 transmission.
5 0 CSI/TSI/CIG transmit
0: Yes
1: No
When set at “1”, transmission of the CSI, TSI and
CIG signals are disabled.
4 0 ECM mode
0: On
1: Off
Determines ECM mode. ECM mode reduces
document memory and may lengthen transmission
and reception times.
3
0
Retransmit automatically
when receiving RTN/PIN
signals
0: Yes
1: No
When set to “1”, retransmission disables
automatically if receiving RTN/PIN signals.
2
1
Factory use only
1
0
Factory use only
0
0
Factory use only
Memory Switch B:4 --- Factory use only