Specifications

3-45
Memory Switch 63 - Remote reception and TAD interface
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 1
5 0
4 1
Adjust silent detection time This switch adjusts the length of silence required
for silent detection activation.
Switch 7 6 5 4 Time
0 0 0 0 0 sec
0 0 0 1 1 sec
0 0 1 0 2 sec
0 0 1 1 3 sec
0 1 0 0 4 sec
0 1 0 1 5 sec
Initial setting
0 1 1 0 6 sec
0 1 1 1 7 sec
1 0 0 0 8 sec
1 0 0 1 9 sec
1 0 1 0 10 sec
1 0 1 1 11 sec
1 1 0 0 12 sec
1 1 0 1 13 sec
1 1 1 0 14 sec
1 1 1 1 15 sec
3 0
2 1
1 1
0 0
Number of seconds silent
detection remains active
This switch adjusts the length of time silence
detection remains active.
Switch 3 2 1 0 Time
0 0 0 0 0 sec
0 0 0 1 10 sec
0 0 1 0 20 sec
0 0 1 1 30 sec
0 1 0 0 40 sec
0 1 0 1 50 sec
0 1 1 0 60 sec
Initial setting
0 1 1 1 70 sec
1 0 0 0 80 sec
1 0 0 1 90 sec
1 0 1 0 100 sec
1 0 1 1 110 sec
1 1 0 0 120 sec
1 1 0 1 130 sec
1 1 1 0 140 sec
1 1 1 1 150 sec