Specifications

5
Machine Parameter 30 <- F-320 Only)
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 1
1 0
0 0
Slice level adjustment of
“Light” in the mode without
Grayscale. (For ADF)
Switch 3210
0000 Lightest setting
0001
0100 Initial setting
0111
1000 Darkest setting
Machine Parameter 32 <- F-320 Only)
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 1
1 0
0 0
Slice level adjustment of
“Normal in the mode without
Grayscale. (For ADF)
Switch 3210
0000 Lightest setting
0001
0100 Initial setting
0111
1000 Darkest setting
Machine Parameter 34 <- F-320 Only)
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 1
1 0
0 0
Slice level adjustment of
“Dark” in the mode without
Grayscale. (For ADF)
Switch 3210
0000 Lightest setting
0001
0100 Initial setting
0111
1000 Darkest setting