Specifications

3-115
3.13.2 Tonal Signal Test
The tonal signal test permits the unit’s output tones to be monitored.
Note: To monitor the tones, an external monitoring device must be connected to the telephone line jack.
1. Press MENU, *, 1, 2.
2. Press the numeric keypad 0 (zero) to select the main board.
To select the optional board number for the second phone line, press 1 (one).
Then press ENTER.
3. Select “Tonal Test”, then press ENTER.
4. Select the desired tonal signal using cursor key.
Refer to the following table.
No. Signal No. Signal
01 None (stop signal) 11 FSK black (all 1)
02 462 Hz tone 12 FSK White 1 : Black 1
03 1080 Hz tone 13 V27_1200_2400 picture data
04 1300 Hz tone 14 V27_1600_4800 picture data
05 1650 Hz tone 15 V27_2400_7200 picture data
06 1700 Hz tone 16 V27_2400_9600 picture data
07 1800 Hz tone 17 V17_2400_7200 picture data
08 1850 Hz tone 18 V17_2400_9600 picture data
09 2100 Hz tone 19 V17_2400_12000 picture data
10 FSK white (all 0) 20 V27_2400_14400 picture data
No. Signal No. Signal
21 – 29 V34_2400_2400 to 21600 51 – 62 V34_3200_4800 to 31200
30 – 39 V34_2800_4800 to 26400 63 – 75 V34_34290_4800 to 33600
40 – 50 V34_3000_4800 to 28800 76 Voice