Data Sheet

Copyright © Murata Manufacturing Co., Ltd. All rights reserved. October 2018
LBAD0ZZ1SE Data Sheet, v1.0, 10/05/2020 Page 6 of 26 www.murata.com
4 DC Electrical Specification
4.1 Tx Output Power
The module is compliant to the 3GPP spec for release 13 and rated at a Class 3 device (23 dBm)
4.2 Rx Sensitivity
Table 4-1 Rx Sensitivity
Items
Contents
Min
Typ.
Max
Unit
Frequency Range
LB
703
960
MHz
MB
1710
2170
MHz
Rx Sensitivity
MCS5, BER<5%
-103
dBm
5 Environmental Specification
5.1 Absolute Maximum Rating
Table 5-1 Absolute Maximum Rating
Description
Min
Max
Unit
VDD
-0.3
6
V
PA Stability
6:1
VSWR
5.2 Recommended Operating Condition
Table 5-2 Recommended Operating Condition
Parameter
Min
Max
Unit
Operating Temperature Range
-40
85
°C
VDD
3.3
5.0
V
5.3 Temperature Range
Table 5-3 Temperature Range
Range
Note
Storage temperature range
-40 ºC 85 ºC
Storage and non-operational
Operating temperature range
-40 ºC 85 ºC
Module is fully functional
-10 ºC 55 ºC
Module is fully functional
and
fully meets 3GPP specification
(†) Functional: the module is able to connect to PDN and transfer data.