Datasheet
Table Of Contents
- CONTENTS
- Part Numbering
- SMD-Dual Type Pyroelectric Infrared Sensor IRS-B210ST01 Series
- Parallel Quad Type Pyroelectric Infrared Sensor IRS-B340ST02 Series
- Dual Type Pyroelectric Infrared Sensor IRA-E700 Series
- Quad Type Pyroelectric Infrared Sensor IRA-E900 Series
- Pyroelectric Infrared Sensor IRS/IRA Series Characteristics Data
- Pyroelectric Infrared Sensors/Lens
- Notice

5
9
Note
• Please read rating and CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please review our product specifications or consult the approval sheet for product specifications before ordering.
After test completion, leave for three hours in
normal humidity temperature conditions, and
then measure.
1. External appearance:
No significant damage
2. Sensitivity:
Tolerance within 20% deviation from original
value
3. Noise:
Maximum tolerance +100mV of original value
No generation of bubbles
▊
Reliability Test
IRS series, IRA-E700 series, IRA-E900 series
Item
High Temperature
Low Temperature
Humidity
Heat Cycle
Vibration
Shock
Soldering Heat
Hermetic Sealing
100℃ for 500 hrs.
—4 0 ℃ for 500 hrs.
60℃, 95% RH for 500 hrs.
20 times of following cycle.
—2 5 ℃, 30 min. ⇨Room temp., 30 min.⇩
⇧Room temp., 30 min. ⇦55℃, 30 min.
Apply vibration of amplitude of 1.5mm with 10 to 55Hz band to each of 3
perpendicular directions for 60 min.
Apply shock of 100G sine wave by standard shock tester to each of 3
perpendicular directions.
Immerse up to 3.0mm from can case in solder bath of 260±5℃ for 10±1 s.
Conform to MIL-STD-202F chapter 112D, condition D.
Immerse in fluorocarbon bath (FC-40) of 125±5℃ for 20 s.
Test Conditions
Criteria
Pyroelectric Infrared Sensor IRS/IRA Series Characteristics Data
S21E.pdf
MAY.16,
2011