Datasheet
http://www.murata-ps.com/data/power/uwq.pdf
➀ Please refer to the part number structure for additional ordering information and options.
➁ All specifi cations are typical at nominal line voltage and full load, +25°C unless otherwise noted. See
detailed specifi cations. Output capacitors are 1 µF || 10 µF with a 22µF input capacitor. These caps are
necessary for our test equipment and may not be needed for your application.
ORDERING GUIDE ➀
Root Model ➀
Output Input
Effi ciency Dimensions
VOUT
(Volts)
IOUT
(Amps,
max.)
Power
(Watts)
R/N (mV
pk-pk) Regulation (Max.) ➁
VIN Nom.
(Volts)
Range
(Volts)
IIN no
load (mA)
IIN full
load
(Amps)Typ. Max. Line Load Min. Typ. (inches) (mm)
UWQ-12/17-Q48T-C
UWQ-12/17-Q48T-C ➁
12 17 204 100 120 ±0.25% ±0.3% 48 18-75 80 4.62 90% 92%
2.30x1.45x0.46 max.
2.30x1.45x0.46 max.
58.4x36.8x11.7
58.4x36.8x11.7
PART NUMBER STRUCTURE
UWQ Pin 9 Baseplate Connection
The UWQ module has an additional pin 9 on special order that connects to the baseplate but is
electrically isolated from the rest of the converter. Please refer to the mechanical drawings.
Pin 9 offers a positive method of controlling the electrical potential of the baseplate, indepen-
dent of the converter.
The baseplate may be ordered by adding a “B” to the model number tree and pin 9 will be pre-
installed by adding a “9.” The two options are separate. Please refer to the Ordering Guide. Do
not order pin 9 without the baseplate. Note that “pin 9” converters may be on limited forecast,
requiring minimum order quantities and scheduled deliveries.
Pin length option
Blank = standard pin length 0.188 in. (4.78 mm)
L1 = 0.110 in. (2.79 mm)*
L2 = 0.145 in. (3.68 mm)*
Lx
Q48
Input Voltage Range:
Q48 = 18-75 Volts (48V nominal)
/
Nominal Output Voltage
12 17
Maximum Rated Output :
Current in Amps
-
N
On/Off Control Logic
N = Negative logic
P = Positive logic
-
UWQ
Family
Series:
Wide Input
Quarter Brick
Baseplate Option
Blank = No baseplate, standard
B = Baseplate installed, optional
B
Trim & Sense
T = Trim & Sense pins included
**
T
RoHS Hazardous Materials compliance
C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder), standard
-
C
Complete Model Number Example:
Negative On/Off logic, trim & sense included, baseplate installed, 0.110˝ pin length, RoHS-6 compliance
UWQ-12/17-Q48NTBL1-C
*Special quantity order is required;
no sample quantities available.
**If Trim & Sense pins are not
required, please click here for the UWQ
series (UWQ-12/17-Q48) data sheet, or
contact Murata Power Solutions.
Note:
Some model number combinations
may not be available. Please contact
Murata Power Solutions.
9
Baseplate Connect Pin 9 (special order)*
Blank = No pin 9, standard
9 = Pin 9 installed, connects to baseplate
UWQ-12/17-Q48T-C Series
Wide Input, Isolated DOSA Quarter Brick
DC-DC Converters with Trim and Sense
MDC_UWQ-12-17-Q48T-C.A01 Page 2 of 17
www.murata-ps.com/support