Datasheet

http://www.murata-ps.com/data/power/uwq.pdf
Please refer to the part number structure for additional ordering information and options.
All specifi cations are typical at nominal line voltage and full load, +25°C unless otherwise noted. See
detailed specifi cations. Output capacitors are 1 µF || 10 µF with a 22µF input capacitor. These caps are
necessary for our test equipment and may not be needed for your application.
ORDERING GUIDE
Root Model
Output Input
Effi ciency Dimensions
VOUT
(Volts)
IOUT
(Amps,
max.)
Power
(Watts)
R/N (mV
pk-pk) Regulation (Max.)
VIN Nom.
(Volts)
Range
(Volts)
IIN no
load (mA)
IIN full
load
(Amps)Typ. Max. Line Load Min. Typ. (inches) (mm)
UWQ-12/17-Q48T-C
UWQ-12/17-Q48T-C
12 17 204 100 120 ±0.25% ±0.3% 48 18-75 80 4.62 90% 92%
2.30x1.45x0.46 max.
2.30x1.45x0.46 max.
58.4x36.8x11.7
58.4x36.8x11.7
PART NUMBER STRUCTURE
UWQ Pin 9 Baseplate Connection
The UWQ module has an additional pin 9 on special order that connects to the baseplate but is
electrically isolated from the rest of the converter. Please refer to the mechanical drawings.
Pin 9 offers a positive method of controlling the electrical potential of the baseplate, indepen-
dent of the converter.
The baseplate may be ordered by adding a “B” to the model number tree and pin 9 will be pre-
installed by adding a “9.” The two options are separate. Please refer to the Ordering Guide. Do
not order pin 9 without the baseplate. Note that “pin 9” converters may be on limited forecast,
requiring minimum order quantities and scheduled deliveries.
Pin length option
Blank = standard pin length 0.188 in. (4.78 mm)
L1 = 0.110 in. (2.79 mm)*
L2 = 0.145 in. (3.68 mm)*
Lx
Q48
Input Voltage Range:
Q48 = 18-75 Volts (48V nominal)
/
Nominal Output Voltage
12 17
Maximum Rated Output :
Current in Amps
-
N
On/Off Control Logic
N = Negative logic
P = Positive logic
-
UWQ
Family
Series:
Wide Input
Quarter Brick
Baseplate Option
Blank = No baseplate, standard
B = Baseplate installed, optional
B
Trim & Sense
T = Trim & Sense pins included
**
T
RoHS Hazardous Materials compliance
C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder), standard
-
C
Complete Model Number Example:
Negative On/Off logic, trim & sense included, baseplate installed, 0.110˝ pin length, RoHS-6 compliance
UWQ-12/17-Q48NTBL1-C
*Special quantity order is required;
no sample quantities available.
**If Trim & Sense pins are not
required, please click here for the UWQ
series (UWQ-12/17-Q48) data sheet, or
contact Murata Power Solutions.
Note:
Some model number combinations
may not be available. Please contact
Murata Power Solutions.
9
Baseplate Connect Pin 9 (special order)*
Blank = No pin 9, standard
9 = Pin 9 installed, connects to baseplate
UWQ-12/17-Q48T-C Series
Wide Input, Isolated DOSA Quarter Brick
DC-DC Converters with Trim and Sense
MDC_UWQ-12-17-Q48T-C.A01 Page 2 of 17
www.murata-ps.com/support