Datasheet

UWQ-12/17-Q48 Series
Wide Input, Isolated DOSA Quarter Brick DC/DC Converters
MDC_UWQ-12/17-Q48 Series.A06 Page 4 of 17
www.murata-ps.com/support
OUTPUT
Conditions
Minimum Typical/Nominal Maximum Units
Total Output Power 0.0 204 210 W
Voltage
Setting Accuracy, fi xed output At 50% load, not user adjustable 11.64 12 12.36 Vdc
Overvoltage Protection Via magnetic feedback 15 Vdc
Current
Output Current Range 0.0 17 17 A
Minimum Load No minimum load
Current Limit Inception 97% of Vnom., cold condition 19 21 23 A
Short Circuit
Short Circuit Current
Hiccup technique, autorecovery within 1.25%
of Vout
56A
Short Circuit Duration
(remove short for recovery)
Output shorted to ground, no damage Continuous
Short circuit protection method Hiccup current limiting Non-latching
Regulation
Line Regulation Vin=min. to max., Vout=nom., full load ±0.65 % of Vout
Load Regulation Iout=min. to max., Vin=nom. ±1.5 % of Vout
Ripple and Noise
5 Hz- 20 MHz BW, Cout=1µF MLCC paralleled
with 10µF tantalum
100 120 mV pk-pk
Temperature Coeffi cient At all outputs 0.02 % of Vout./°C
Maximum Capacitive Loading Full resistive load, low ESR 0 5000 F
MECHANICAL (Through Hole Models)
Outline Dimensions (no baseplate) 2.3x1.45x0.46 max. Inches
(Please refer to outline drawing) LxWxH 58.4x36.8x11.68 mm
Outline Dimensions (with baseplate) 2.3x1.45x0.5 Inches
58.4x36.8x12.7 mm
Weight No baseplate 1.6 Ounces
No baseplate 45 Grams
With baseplate 2.24 Ounces
With baseplate 63.5 Grams
Through Hole Pin Diameter 0.04 & 0.06 Inches
1.016 & 1.52 mm
Through Hole Pin Material Copper alloy
TH Pin Plating Metal and Thickness Nickel subplate 50 µ-inches
Gold overplate 5 µ-inches
Baseplate Material Aluminum
ENVIRONMENTAL
Operating Ambient Temperature Range See derating curves -40 85 °C
Operating Case Temperature With baseplate, no derating -40 110 °C
Storage Temperature Vin = Zero (no power) -55 125 °C
Thermal Protection/Shutdown Measured in center 115 125 130 °C
Electromagnetic Interference External fi lter is required
Conducted, EN55022/CISPR22 B Class
Radiated, EN55022/CISPR22 B Class
RoHS rating RoHS-6
FUNCTIONAL SPECIFICATIONS, (CONT.)
Notes
Unless otherwise noted, all specifi cations apply at Vin = nominal, nominal output voltage and full
output load. General conditions are near sea level altitude, no base plate installed and natural
convection airfl ow unless otherwise specifi ed. All models are tested and specifi ed with external
parallel 1 F and 10 F multi-layer ceramic output capacitors and a 22µF external input capacitor
(see Technical Notes). All capacitors are low-ESR types wired close to the converter. These capaci-
tors are necessary for our test equipment and may not be needed in the user’s application.
Input (back) ripple current is tested and specifi ed over 5 Hz to 20 MHz bandwidth. Input fi ltering is
Cin = 33 µF/100V, Cbus = 220µF/100V and Lbus = 12 µH.
All models are stable and regulate to specifi cation under no load.
The Remote On/Off Control is referred to -Vin.
Regulation specifi cations describe the output voltage changes as the line voltage or load current
is varied from its nominal or midpoint value to either extreme. The load step is ±25% of full load
current.
Output Ripple and Noise is measured with Cout = 1 µF || 10 µF, 20 MHz oscilloscope bandwidth
and full resistive load.