UWE-100-120W Series www.murata-ps.com Wide Input, Isolated Eighth-Brick DC-DC Converters The UWE Series "Eighth-Brick" DC-DC Converters are high-current isolated power modules designed for use in high-density system boards. Typical units FEATURES PRODUCT OVERVIEW Industry-standard through-hole eighth-brick package Wide input range of 18-75Vdc or 9-36Vdc (12Vout only) Fixed outputs from 3.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters SPECIFICATION SUMMARY AND ORDERING GUIDE ➁➂ Output Input R/N (mVp-p) Regulation (%) Efficiency IIN, min IIN, full VIN Nom. Range load load Min. (V) (V) (mA) (A) Dimensions VOUT (V) ➃ IOUT (A) Power (W) Typ. Max. Line Load 3.3 30 99 90 125 ±0.2 ±0.2 48 18-75 90 2.30 88% 89.5% 2.3x0.9x0.39 58.42x22.86x9.91 UWE-5/20-Q48-C 5 20 100 75 110 ±0.1 ±0.2 48 18-75 100 2.30 89% 90.5% 2.3x0.9x0.39 58.42x22.86x9.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters FUNCTIONAL SPECIFICATIONS, UWE-3.3/30-Q48 ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Input Voltage, Transient Isolation Voltage Input Reverse Polarity On/Off Remote Control Output Power CONDITIONS AND COMMENTS ➀ Full power operation Operating or non-operating, 100 mS max.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters FUNCTIONAL SPECIFICATIONS, UWE-3.3/30-Q48 (CONT.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-3.3/30-Q48 Efficiency vs. Line Voltage and Load Current @ 25°C Power Dissipation vs.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-3.3/30-Q48 Startup Delay (Vin=48V, Iout=0A, Cout=0, Ta=+25°C) Trace1=Vin, Trace2=Vout. Startup Delay (Vin=48V, Iout=30A, Cout=0, Ta=+25°C) Trace1=Vin, Trace2=Vout. Startup Delay (Vin=48V, Iout=30A, Cout=10000μF, Ta=+25°C) Trace1=Vin, Trace2=Vout. On/Off Enable Delay (Vin=48V, Iout=0A, Cout=0, Ta=+25°C) Trace1=Enable, race2=Vout.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-3.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters FUNCTIONAL SPECIFICATIONS, UWE-5/20-Q48-C ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Input Voltage, Transient Isolation Voltage Input Reverse Polarity On/Off Remote Control Output Power CONDITIONS AND COMMENTS ➀ Full power operation Operating or non-operating, 100 mS max.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters FUNCTIONAL SPECIFICATIONS, UWE-5/20-Q48-C (CONT.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-5/20-Q48-C Efficiency vs. Line Voltage and Load Current @ 25°C Power Dissipation vs.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-5/20-Q48-C Startup Delay (Vin=48V, Iout=0A, Cout=0, Ta=+25°C) Trace1=Vin, Trace2=Vout. Startup Delay (Vin=48V, Iout=20A, Cout=0, Ta=+25°C) Trace1=Vin, Trace2=Vout. Startup Delay (Vin=48V, Iout=20A, Cout=10000μF, Ta=+25°C) Trace1=Vin, Trace2=Vout. On/Off Enable Delay (Vin=48V, Iout=0A, Cout=0, Ta=+25°C) Trace1=Enable, Trace2=Vout.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-5/20-Q48-C Stepload Transient Response (Vin=48V, Iout=50-75-50% of Iout, Cload= 1μF || 10μF , Slew rate: 10A/uS at Ta=+25°C) Stepload Transient Response (Vin=48V, Iout=50-75-50% of Iout, Cload= 1μF || 10μF ||10000μF , Slew rate: 10A/uS at Ta=+25°C) Output Ripple and Noise (Vin=48V, Vout=nom, Iout=0A, Cout=1F || 10μF, Ta=+25°C, ScopeBW=20Mhz) Output Ripple and Noise (Vin=48V, Vout=nom, Iout=20A, Cout=1F || 10μF, T
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters FUNCTIONAL SPECIFICATIONS, UWE-12/10-Q48 ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Input Voltage, Transient Isolation Voltage Input Reverse Polarity On/Off Remote Control Output Power CONDITIONS AND COMMENTS ➀ Full power operation Operating or non-operating, 100 mS max.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters FUNCTIONAL SPECIFICATIONS, UWE-12/10-Q48 (CONT.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-12/10-Q48 Efficiency vs. Line Voltage and Load Current @ 25°C Power Dissipation vs.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-12/10-Q48 Startup Delay (Vin=48V, Iout=0A, Cout=0, Ta=+25°C) Trace1=Vin, Trace2=Vout. Startup Delay (Vin=48V, Iout=10A, Cout=0, Ta=+25°C) Trace1=Vin, Trace2=Vout. Startup Delay (Vin=48V, Iout=10A, Cout=4700μF, Ta=+25°C) Trace1=Vin, Trace2=Vout. On/Off Enable Delay (Vin=48V, Iout=0A, Cout=0, Ta=+25°C) Trace1=Enable, Trace2=Vout. On/Off Enable Delay (Vin=48V, Iout=10A, Cout=0, Ta=+25°C) Trace1=Enable, Trace2=Vout.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-12/10-Q48 Stepload Transient Response (Vin=48V, Iout=50-100-50% of Iout, Cload= 1μF || 10μF, Slew rate: 5A/uS at Ta=+25°C) Stepload Transient Response (Vin=48V, Iout=50-100-50% of Iout, Cload= 1μF || 10μF || 4700μF, Slew rate: 5A/uS at Ta=+25°C) Stepload Transient Response (Vin=48V, Iout=50-75-50% of Iout, Cload= 1μF || 10μF || 4700μF, Slew rate: 5A/uS at Ta=+25°C) Output Ripple and Noise (Vin=48V, Vout=nom, Iout
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-12/10-Q48 Thermal image with hot spot at 8.24A current with 25°C ambient temperature. Natural convection is used with no forced airflow. Identifiable and recommended maximum value to be verified in application. Vin=48V, Q14 is the hot spot. www.murata-ps.com/support MDC_UWE-100-120W.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters FUNCTIONAL SPECIFICATIONS, UWE-12/10-Q12 ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Input Voltage, Transient Isolation Voltage Input Reverse Polarity On/Off Remote Control Output Power CONDITIONS AND COMMENTS ➀ Full power operation Operating or non-operating, 100 mS max. duration Input to output None, install external fuse Power on or off, referred to -Vin MINIMUM TYPICAL/NOMINAL MAXIMUM 36 UNITS Vdc 50 Vdc 15 121.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters FUNCTIONAL SPECIFICATIONS, UWE-12/10-Q12 (CONT.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-12/10-Q12 Efficiency vs. Line Voltage and Load Current @ 25°C Power Dissipation vs. Line and Load 15 95 Dissipation (Watts) 90 Efficiency (%) 85 Vin = 9V Vin = 12V Vin = 18V Vin = 24V Vin = 30V Vin = 36V 80 75 10 Vin = 9V Vin = 12V Vin = 18V Vin = 24V Vin = 30V Vin = 36V 5 70 65 0 1 2 3 4 5 6 7 8 9 10 1 2 3 4 11 10 10 9 9 Output Current (Amps) Output Current (Amps) 11 8 0.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-12/10-Q12 Maximum Current Temperature Derating @sea level (VIN = 18V, air flow from Pin 1 to Pin 3, with baseplate) 11 11 10 10 9 Output Current (Amps) Output Current (Amps) Maximum Current Temperature Derating @ sea level (VIN = 18V, air flow from Pin 1 to Pin 3, no baseplate) 0.33 m/s (65 LFM) 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 8 7 6 9 0.33 m/s (65 LFM) 0.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-12/10-Q12 Startup Delay (Vin=12V, Iout=0A, Cout=0, Ta=+25°C) Trace1=Vin, Trace2=Vout. Startup Delay (Vin=12V, Iout=10A, Cout=0, Ta=+25°C) Trace1=Vin, Trace2=Vout. Startup Delay (Vin=12V, Iout=10A, Cout=5000μF, Ta=+25°C) Trace1=Vin, Trace2=Vout. On/Off Enable Delay (Vin=12V, Iout=0A, Cout=0, Ta=+25°C) Trace1=Enable, Trace2=Vout. On/Off Enable Delay (Vin=12V, Iout=10A, Cout=0, Ta=+25°C) Trace1=Enable, Trace2=Vout.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-12/10-Q12 Stepload Transient Response (Vin=12V, Iout=50-100-50% of Iout, Cload= 1μF || 10μF, Slew rate: 5A/uS at Ta=+25°C) Stepload Transient Response (Vin=12V, Iout=50-100-50% of Iout, Cload= 1μF || 10μF || 5000μF, Slew rate: 5A/uS at Ta=+25°C) Stepload Transient Response (Vin=12V, Iout=50-75-50% of Iout, Cload= 1μF || 10μF || 5000μF, Slew rate: 5A/uS at Ta=+25°C) Output Ripple and Noise (Vin=12V, Vout=nom, Iout
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters PERFORMANCE DATA, UWE-12/10-Q12 Thermal image with hot spot at 8.66A current with 25°C ambient temperature. Natural convection is used with no forced airflow. Identifiable and recommended maximum value to be verified in application. Vin=12V, Q6 is the hot spot. www.murata-ps.com/support MDC_UWE-100-120W.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters MECHANICAL SPECIFICATIONS—NO BASEPLATE 2.30 (58.4) TOP VIEW ISOMETRIC VIEW 0.90 (22.9) 0.071 (1.8)±.002 STANDOFF AT EACH 0.040 (1.02) PIN MTG PLANE 0.126 (3.17) SIDE VIEW 0.010 (0.254) MIN (HIGHEST COMP TO MTG PLANE) END VIEW Q12 = 0.39 0.34 (9.91) (8.64) 0.125 (3.175) REF 0.19 (4.83) 0.040 (1.02) ±.002 AT PINS 1-3, 5-7 0.062 (1.57) ±.002 AT PINS 4 & 8 DOSA-Compatible I/O Connections 0.15 (3.8) 2.000 (50.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters MECHANICAL SPECIFICATIONS (continued)—BASEPLATE INSTALLED See Note 1. Note 1. The (2) M3 holes are not installed on the baseplate of the UWE-12/10-Q12xB-C. Dimensions are in inches (mm shown for ref. only). Third Angle Projection Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ Components are shown for reference only. www.murata-ps.com/support MDC_UWE-100-120W.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters SHIPPING TRAYS AND BOXES Anti-static foam Label Label SHIPPING TRAY UWE modules are supplied in a 21-piece (3-by-7) shipping tray. The tray is an anti-static closed-cell polyethylene foam. Dimensions are shown below. 0.910 (23.1) TYP 9.920 (252) +0.000 -0.062 0.455 (11.6) TYP 0.735 (18.7) 9.920 (252) +0.000 -0.062 0.625 (15.9) TYP 2.400 (61) TYP Dimensions in inches (mm) 1.300 (33.0) TYP 1.06 (26.9) 0.25 R TYP 0.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters TECHNICAL NOTES Input Fusing Certain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. Fuses should also be used if the possibility of sustained, non-current-limited, input-voltage polarity reversals exist. For MPS UWE DC-DC Converters, you should use fast-blow type fuses, installed in the ungrounded input supply line. Refer to the specifications for fuse values.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters +SENSE +VOUT C1 C2 SCOPE RLOAD –VOUT –SENSE C1 = 1μF C2 = 10μF LOAD 2-3 INCHES (51-76mm) FROM MODULE Figure 4. Measuring Output Ripple/Noise (PARD) Floating Outputs Since these are isolated DC-DC converters, their outputs are "floating" with respect to their inputs. Designers will normally use the –Output as the ground/ return of the load circuit.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters Trim Equations +VOUT +VIN Trim Up +SENSE ON/OFF CONTROL Trim Down 3.3 Volt Output 1MΩ 5-20 TURNS TRIM LOAD RT UP (kΩ) = –SENSE 13.3(VO – 1.226) –10.2 VO – 3.3 RTDOWN (kΩ) = 16.31 –10.2 3.3 – VO 5 Volt Output –VIN –VOUT RT UP (kΩ) = Figure 6. Trim Connections Using a Trimpot 20.4(VO – 1.226) –10.2 VO – 5 RTDOWN (kΩ) = 25.01 5 – VO –10.2 12 Volt Output +VIN +VOUT RT UP (kΩ) = 49.6(VO – 1.226) VO – 12 –10.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters Remote Sense Note The Sense and VOUT lines are internally connected through low value resistors. Nevertheless, if the sense function is not used for remote regulation the user should connect the +Sense to +VOUT and –Sense to –VOUT at the DC-DC converter pins. UWE series converters have a sense feature to provide point of use regulation, thereby overcoming moderate IR drops in pcb conductors or cabling.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters Emissions Performance The sample was tested in accordance with CISPR/EN55022 requirements. Class B limits were applied for this test. The EUT was supplied with 48Vdc (nominal) and was loaded to the maximum rating 120 Watts. The noise was measured on the return side of supply. The following EMI filter components were employed.
UWE-100-120W Series Wide Input, Isolated Eighth-Brick DC-DC Converters Vertical Wind Tunnel IR Transparent optical window Unit under test (UUT) Variable speed fan IR Video Camera Murata Power Solutions employs a computer controlled custom-designed closed loop vertical wind tunnel, infrared video camera system, and test instrumentation for accurate airflow and temperature distribution measurements of power products.