Datasheet

www.murata-ps.com/support
UQQ Series
Wide Input Range Single Output DC-DC Converters
MDC_UQQ.D05 Page 4 of 18
UQQ-12/8-Q48 UQQ-15/7-Q12 UQQ-24/4-Q12
INPUT
Input Voltage Range See ordering guide
Start-up Threshold 17.5 Volts 9.0 Volts (18) 9.0 Volts (18)
Undervoltage Shutdown 16.0 Volts 8.0 Volts 8.0 Volts
Overvoltage Shutdown None 38.5 Volts None
Refl ected (back) ripple current (2) 15mAp-p 50mAp-p 50mAp-p
Input Current
Full load conditions See ordering guide
Inrush transient 0.1A
2
sec
Output short circuit 100mA 250mA 250mA
No load 70mA 250mA 120mA
Low line (V
IN = min.) 5.93A 12.9 Amps 10.73 Amps
Standby mode
(Off, UV, OT shutdown)
30mA 30mA
5mA
Internal Input Filter Type PI-type L-C L-C
Reverse Polarity Protection
External Fusing
Required (15)
External Fusing
Required (15)
External Fusing
Required (15)
Remote On/Off Control (5)
Positive logic (“P” suffi x)
OFF = Ground pin to +0.8V max. ON = open or +3.5-15V max.
Negative logic (“N” suffi x)
OFF = open or +5 to +V
IN max. ON = Ground pin to +0.8V max. (16)
On/Off Current 1 mA
OUTPUT
Voltage Output Range See ordering guide
Voltage Output Accuracy
(50% load)
±1.25% of V
NOM ±1% of VNOM ±1% of VNOM
Adjustment Range –20 to +10% of VNOM –20 to +10% of VNOM ±10% of VNOM
Temperature Coeffi cient ±0.02% of
V
OUT range/°C
Minimum Loading No minimum loading
Remote Sense Compensation +10% of Vout max. +10% of Vout max. +10% of Vout max.
Ripple/noise (20MHz bandwidth)
See ordering guideLine/Load Regulation
Effi ciency
Maximum Capacitive Loading
Low ESR <0.02max., resistive load
2200µF 4700F 1500F max
Isolation Voltage
Input to Output 2250 VDC min. 2000 VDC min. 2000 VDC min.
Input fo baseplate 1500 VDC min. 1500 VDC min. 1500 VDC min.
Baseplate to Output 500 VDC min. 1500 VDC min. 1500 VDC min.
Isolation resistance 100M 100M 100M
Isolation capacitance 1000 pF 1000 pF 1000 pF
Isolation safety rating Basic insulation
Current limit inception
(98% of V
OUT, after warmup)
11.5 Amps 9.5 Amps 5.75 Amps
Short Circuit Protection Method Current limiting, hiccup autorestart. Remove overload for recovery
Short Circuit Current 0.1 Amps 0.5 Amps 0.5 Amps
Short Circuit Duration Continuous, output shorted to ground (no damage)
Overvoltage Protection
via magnetic feedback
15 Volts 18 Volts 29 Volts
Absolute Maximum Ratings
Input Voltage 12V models 48V models
Continuous 0 to +36V 0 to +75V
Transient (100msec) +50V +100V
On/Off Control 0V min to +15V max.
Input Reverse Polarity Protection Install external fuse.
Output Overvoltage VOUT +20% max.
Output Current
(7)
Current-limited. Devices can
withstand sustained short circuit
without damage.
Storage Temperature –55 to +125°C
Lead Temperature See soldering guidelines
Absolute maximums are stress ratings. Exposure of devices to greater than
any of these conditions may adversely affect long-term reliability. Proper
operation under conditions other than those listed in the Performance/
Functional Specifi cations Table is not implied or recommended.
FUNCTIONAL SPECIFICATIONS (CONTINUED)