Datasheet

www.murata-ps.com/support
ULS 60-Watt Series
Sixteenth-brick DOSA-Compatible,
Isolated DC/DC Converters
MDC_ULS Series.C02 Page 22 of 24
DOWN
RT (k) =
Where ∆% =
|(
× 100
)|
10.22
∆%
511
Trim Down
Trim Equations
Trim Up
UP
RT (k) =
1.225 × ∆%
5.11 × VNOM × (100 + ∆%)
∆%
511
10.22
VNOM – VDES
VNOM
Note:∆%” is always a positive value.
“V
NOM is the nominal, rated output voltage.
“V
DES is the desired, changed output voltage.
Figure 7. Trim Connections To Increase Output Voltages
Connect sense to its respective Vout pin if sense is not used with a remote load.
LOAD
R
TRIM UP
+VOUT
+VIN
–VIN
ON/OFF
CONTROL
TRIM
+SENSE
–VOUT
–SENSE
LOAD
R
TRIM DOWN
+VOUT
+VIN
–VIN
ON/OFF
CONTROL
TRIM
+SENSE
–VOUT
–SENSE
Figure 8. Trim Connections To Decrease Output Voltages
OUTPUT VOLTAGE ADJUSTMENT
Dynamic control of the remote on/off function is best accomplished with a
mechanical relay or an open-collector/open-drain drive circuit (optically isolated
if appropriate). The drive circuit should be able to sink appropriate current (see
Performance Specifications) when activated and withstand appropriate voltage
when deactivated. Applying an external voltage to pin 2 when no input power is
applied to the converter can cause permanent damage to the converter.
+Vcc
13V CIRCUIT
5V CIRCUIT
–VIN
O N /O F F
C O N TR O L
+VIN
Figure 6. Driving the Negative Logic On/Off Control Pin
(simplified circuit)