ULS 30-Watt Series www.murata-ps.com Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters FEATURES Small footprint DC/DC converter, ideal for embedded applications 1.30" x 0.90" x 0.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE Output Root Model ULS-3.3/8-D48 VOUT (V) IOUT Power (A, max.) (W) Input R/N (mV pk-pk) Typ. Max. Regulation (max.) ➂ Line Load VIN Nom. (V) Range (V) Efficiency IIN, no load (mA) IIN, full load (A) Min. Case (inches) Typ. 3.3 8 26.5 90 130 ±0.1% ±0.1% 48 36-75 75 0.58 89% 90% 1.30x0.90x0.36 5 6 30 75 100 ±0.125% ±0.1% 48 36-75 20 0.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters FUNCTIONAL SPECIFICATIONS, ULS-3.3/8-D48 Conditions ➀ ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Input Voltage, Transient Isolation Voltage Input Reverse Polarity On/Off Remote Control Output Power Minimum Typical/Nominal 0 100 mS max. duration Input to output, continuous None, install external fuse Power on, referred to -Vin Maximum 80 100 2250 None 0 0 15 26.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters FUNCTIONAL SPECIFICATIONS, ULS-3.3/8-D48 (CONT.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters TYPICAL PERFORMANCE CURVES, ULS-3.3/8-D48 92 90 88 86 84 82 80 78 76 74 72 70 68 66 64 Maximum Current Temperature Derating at Sea Level (VIN = 36-75V, airflow is from pin 1 to pin 3) 8 Output Current (Amps) Efficiency (%) Efficiency vs. Line Voltage and Load Current @ 25°C VIN = 75V VIN = 60V VIN = 48V VIN = 36V 0.33 to 2.0 m/s (65 to 400 LFM) 7 6 5 4 3 2 1 0 30 0.00 0.81 1.61 2.41 3.21 4.01 4.81 Load Current (Amps) 5.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters OSCILLOGRAMS, ULS-3.3/8-D48 On/Off Enable Delay (Vin=36V, vout=nom, Iout=8A, Cload =1uF || 10uF, Ta=+25°C, ScopeBW=20Mhz) Trace 1= Enable, Trace 3= Vout. On/Off Enable Delay (Vin=75V, vout=nom, Iout=8A, Cload =1uF || 10uF, Ta=+25°C, ScopeBW=20Mhz) Trace 1= Enable, Trace 3= Vout. Startup Delay (Vin=48V, Vout=nom, Iout=8A, Cload= 1uF || 10 uF, Ta=+25°C, ScopeBW=20Mhz) Trace 1= Vin, Trace3, Vout.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters OSCILLOGRAMS, ULS-3.3/8-D48 Step Load Transient Response (Vin=48V, Vout=nom, Iout=50-100-50% of full load, Cload= 1uF || 10uF, Ta=+25°C, ScopeBW=20Mhz) Step Load Transient Response (Vin=48V, Vout=nom, Iout=50-75-50% of full load, Cload= 1uF || 10uF, Ta=+25°C, ScopeBW=20Mhz) Output Ripple and Noise (Vin=48V, Vout=nom, Iout=8A, Cload= 1uF || 10uF, Ta=+25°C, ScopeBW=20Mhz) www.murata-ps.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters FUNCTIONAL SPECIFICATIONS, ULS-5/6-D48 Conditions ➀ ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Input Voltage, Transient Isolation Voltage Input Reverse Polarity On/Off Remote Control Output Power Minimum Typical/Nominal 0 100 mS max. duration Input to output, continuous None, install external fuse Power on, referred to -Vin Maximum 80 100 2250 None 0 0 15 30.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters FUNCTIONAL SPECIFICATIONS, ULS-5/6-D48 (CONT.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters TYPICAL PERFORMANCE CURVES, ULS-5/6-D48 Maximum Current Temperature Derating at Sea Level (VIN = 36-75V, airflow is from pin 3 to pin 1) 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 7 6 0.33 to 2.0 m/s (65 to 400 LFM) Output Current (Amps) Efficiency (%) Efficiency vs. Line Voltage and Load Current @ 25°C VIN = 75V VIN = 60V VIN = 48V VIN = 36V 5 4 3 2 1 0 30 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 35 6.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters OSCILLOGRAMS, ULS-5/6-D48 Startup Delay (Vin=48V, Iout=6A, Cload=0, Ta=+25°C) Trace1=Vin, Trace4=Vout. Startup Delay (Vin=48V, Iout=6A, Cload=2200uF, Ta=+25°C) Trace1=Vin, Trace4=Vout On/Off Enable Delay (Vin=48V, Iout=6A, Cload=0, Ta=+25°C) Trace1=Enable, Trace4=Vout On/Off Enable Delay (Vin=48V, Iout=6A, Cload=2000uF, Ta=+25°C) Trace1=Enable, Trace4=Vout www.murata-ps.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters OSCILLOGRAMS, ULS-5/6-D48 Output Ripple and Noise (Vin=48V, Iout=0A, Cload= 1uF || 10uf, Ta=+25°C) Output Ripple and Noise (Vin=48V, Iout=6A, Cload= 1uF || 10uf, Ta=+25°C) Step Load Transient Response (Vin=48V, Iout=50-75-50% of Imax, Cload= 1uf || 10uF, Ta=+25°C) www.murata-ps.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters FUNCTIONAL SPECIFICATIONS, ULS-12/2.5-D48 Conditions ➀ ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Input Voltage, Transient Isolation Voltage Input Reverse Polarity On/Off Remote Control Output Power Minimum Typical/Nominal 0 100 mS max.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters FUNCTIONAL SPECIFICATIONS, ULS-12/2.5-D48 (CONT.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters TYPICAL PERFORMANCE CURVES, ULS-12/2.5-D48 Efficiency vs. Line Voltage and Load Current @ 25°C Power Dissipation vs. Load Current @ 25°C 89 4.5 87 4.0 3.5 Loss (Watts) Efficiency (%) 85 83 81 79 VIN = 75V VIN = 60V VIN = 48V VIN = 36V 77 75 0.25 0.48 0.70 0.93 3.0 2.5 2.0 VIN = 75V VIN = 60V VIN = 48V VIN = 36V 1.5 1.0 1.15 1.38 1.60 Load Current (Amps) 1.83 2.05 2.28 0.5 0.3 2.50 0.9 1.2 1.4 1.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters OSCILLOGRAMS, ULS-12/2.5-D48 On/Off Enable Delay (Vin = 48V, Vout = nom., Iout = 2.5A, Cload = 0 μF, Ta = +25°C., ScopeBW = 20MHz) Trace 1 = Enable, Trace 4 = Vout Power On Startup Delay (Vin = 48V, Vout = nom., Iout = 2.5A, Cload = 0 μF, Ta = +25°C., ScopeBW = 20MHz) Trace 1 = Vin, Trace 4 = Vout Step Load Transient Response (Vin = 48V, Vout = nom.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters FUNCTIONAL SPECIFICATIONS, ULS-15/2-D48 Conditions ➀ ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Input Voltage, Transient Isolation Voltage Input Reverse Polarity On/Off Remote Control Output Power Minimum Typical/Nominal 0 100 mS max.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters FUNCTIONAL SPECIFICATIONS, ULS-15/2-D48 (CONT.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters TYPICAL PERFORMANCE CURVES, ULS-15/2-D48 Efficiency vs. Line Voltage and Load Current @ 25°C Power Dissipation vs. Load Current @ 25°C 91 3.5 89 3.0 Loss (Watts) Efficiency (%) 87 85 VIN = 75V VIN = 60V VIN = 48V VIN = 36V 83 81 2.5 2.0 VIN = 75V VIN = 60V VIN = 48V VIN = 36V 1.5 79 1.0 77 75 0.21 0.39 0.57 0.75 0.93 1.11 1.29 Load Current (Amps) 1.47 1.65 1.83 2.01 0.5 0.2 0.4 0.6 0.7 0.9 1.1 1.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters OSCILLOGRAMS, ULS-15/2-D48 On/Off Enable Delay (Vin = 48V, Vout = nom., Iout = 2A, Cload = 0 μF, Ta = +25°C., ScopeBW = 20MHz) Trace 1 = Enable, Trace 4 = Vout Power On Startup Delay (Vin = 48V, Vout = nom., Iout = 2A, Cload = 0 μF, Ta = +25°C., ScopeBW = 20MHz) Trace 1 = Vin, Trace 4 = Vout Step Load Transient Response (Vin = 48V, Vout = nom., Iout = 50-75-50% of full load, Cload = 1 μF ceramic || 10μF tantalum, Ta = +25°C.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters MECHANICAL SPECIFICATIONS, THROUGH-HOLE MOUNT SIDE VIEW END VIEW 0.36 (9.144) 0.18 (4.572) 00.060 @ PINS 4 & 8 0.010 MIN CLEARANCE FINISH: (ALL PINS) GOLD (5u"MIN) OVER NICKEL (50u" MIN) 0.040 @ PINS 1-3, 5-7 BOTTOM PIN VIEW PIN #3 PIN #8 1.30 (33.02) 1.100 (27.94) PIN #4 5* 0.300 (7.62) 6 0.150 (3.81) 0.150 (3.81) 2 0.300 (7.62) ISOMETRIC VIEW 4 3 0.90 (22.86) MATERIAL: .040 PINS: COPPER ALLOY .
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters MECHANICAL SPECIFICATIONS, SURFACE MOUNT (MSL RATING 2) SIDE VIEW END VIEW 0.36 .36 (9.144) 0.010 MIN CLEARANCE 0.062 TYP (ALL PINS) 0.125 REF MATERIAL: SMT CONTACTS: COPPER ALLOY FINISH: (ALL PINS) GOLD (5u"MIN) OVER NICKEL (50u" MIN) BOTTOM PIN VIEW 1.30 (33.02) 1.100 (27.94) 0.90 (22.86) 5* 6 0.300 (7.62) PIN #8 4 3 0.300 (7.62) 0.150 (3.81) PIN #4 CL 0.150 (3.81) 2 8 1 Pin 3 0.550 (13.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters SHIPPING TRAYS AND BOXES, THROUGH-HOLE MOUNT 4.50 (114.3) ±.25 Closed height 11.00 (279.4) ±.25 32 units per tray 4 trays per box 10.50 (266.7) ±.25 Each static dissipative polyethylene foam tray accommodates 32 converters in a 4 x 8 array. SHIPPING TRAY DIMENSIONS Material: Low density, closed cell polyethylene anti-static foam 9.84 (250.00) 9.84 (250.00) 0.47 (12.00) 4-C 0.26 (6.5) 0.87 (22.00) 0.59 (15.00) 1 .3 R0 .
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters TAPE AND REEL INFORMATION (MSL RATING 2) Feed (Unwind) Direction ---- 0.14 (3.556) Pin #1 0.069 (1.75) Round Holes 0.85 (21.59) 1.732 (44.00) 0.354 (9.00) MAX PICKUP NOZZLE 1.26 (32.0) PITCH Oblong Holes Top Cover Tape 13.00 (330.20) TAPE AND REEL (200 UNITS PER REEL) .512 (13.00) 4.00 (101.60) CORE 1.73 (44.0) REF Dimensions are in inches (mm shown for ref. only).
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters TECHNICAL NOTES Input Fusing Certain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. Fuses should also be used if the possibility of sustained, non-current-limited, input-voltage polarity reversals exists.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters Short Circuit Condition When a converter is in current-limit mode, the output voltage will drop as the output current demand increases. If the output voltage drops too low, the magnetically coupled voltage used to develop primary side voltages will also drop, thereby shutting down the PWM controller. Following a time-out period, the PWM will restart causing the output voltage to begin ramping to their appropriate value.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters Remote Sense (ULS-3.3/8-D48 and ULS-5/6-D48 models only) Note: The Sense and VOUT lines are internally connected through low-value resistors. Nevertheless, if the sense function is not used for remote regulation the user should connect the +Sense to +VOUT and –Sense to –VOUT at the DC/DC converter pins.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters Trimming by Using an External Voltage Source 1. The easiest way to trim the output using an external voltage source is to drive the Trim pin directly from a variable source. The following equation can be used to calculate the voltage at the Trim pin. Vtrim = 2 x 1.24 x Vo Vonominal − 1.24 Vo is the output voltage you want; Vonominal is the nominal output voltage; Vtrim is the voltage that should appear at the trim pin. 2.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters Emissions Performance Murata Power Solutions measures its products for radio frequency emissions against the EN 55022 and CISPR 22 standards. Passive resistance loads are employed and the output is set to the maximum voltage. If you set up your own emissions testing, make sure the output load is rated at continuous power while doing the tests.
ULS 30-Watt Series Sixteenth-brick DOSA-Compatible, Isolated DC/DC Converters Vertical Wind Tunnel IR Transparent optical window Unit under test (UUT) Variable speed fan Murata Power Solutions employs a computer controlled custom-designed closed loop vertical wind tunnel, infrared video camera system, and test instrumentation for accurate airflow and heat dissipation analysis of power products.