www.murata-ps.com/support
Output
Overvoltage Protection: Magnetic feedback
1.2V Outputs 1.5-2.1 Volts
1.5V Outputs 1.8-2.4 Volts
1.8V Outputs 2.2-2.8 Volts
2.5V Outputs 2.8 to 3.2 Volts
3.3V Outputs 4 to 4.8 Volts
5V Outputs 6.1-7.5 Volts
12V Outputs 12.7-13.5 Volts
15V Outputs 15.8-16.2 Volts
Maximum Capacitive Loading: 10,000µF (1.2-5VOUT)
(Low ESR capacitor) 2,000µF (12-15VOUT)
Dynamic Characteristics
Dynamic Load Response:
(50-100% load step to ±3% VOUT) 200µsec maximum
Start-Up Time: 8msec typical
VIN to VOUT and On/Off to VOUT 15msec maximum
UHE-15/2000-Q12 30mS typ., 50mS max.
Switching Frequency 150-350kHz (model dependent)
Environmental
MTBF
UHE-12/2500-Q12 5,885,546 hours
Operating Temperature (Ambient): –40 to +85°C with Derating
(see Derating Curves)
Thermal Shutdown +115°C to +130°C
Storage Temperature –55 to +125°C
Flammability UL 94 V-0
Physical
Dimensions 1.6" x 2" x 0.40" (40.64 x 50.8 x 10.16mm)
Case Material Diallyl Phthalate
Pin Material Gold-plated copper alloy
Weight 1.51 ounces (46.9 grams)
Primary to Secondary Insulation Level Basic
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted.
Input
Input Voltage Range:
D12 Models (start up at 10V max.) 9-18 Volts (12V nominal)
Q12 Models (start up at 10V max.) 9-36 Volts (24V nominal)
D24 Models 18-36 Volts (24V nominal)
Q48 Models 18-75 Volts (48V nominal)
D48 Models 36-75 Volts (48V nominal)
Overvoltage Shutdown:
D12 Models 18.5-23 Volts
Q12/D24 Models 37-42 Volts
D48/Q48 Models Not applicable
Start-Up Threshold:
D12/Q12 Models 9.4-10 Volts
D24/Q48 Models 15.5-18 Volts
D48 Models 33.5-36 Volts
Undervoltage Shutdown:
D12/Q12 Models 7.0-8.8 Volts
D24/Q48 Models 15-17 Volts
D48 Models 32-35.5 Volts
Input Current:
Normal Operating Conditions See Ordering Guide
Standby Mode (Off, OV, UV) 5mA
Input Reflected Ripple Current
2.5-10mAp-p
Input Filter Type LC or Pi type
Reverse-Polarity Protection Brief duration, 5A maximum
Remote On/Off Control (Pin 4):
Positive Logic (Standard) On = open, open collector, or to +15V
applied. IIN = 2.6mA max.
Off = pulled low to 0-0.8V. IIN = 2mA max.
Negative Logic ("N" Suffix Models) On = pulled low to 0-0.8V. IIN = 6mA max.
Off = open, open collector or to +15V
applied. IIN = 1mA max.
Output
VOUT Accuracy (50% load):
Initial ±1.5%
Temperatue Coefficient ±0.02% per °C
Extreme
(5)
±3%
Minimum Loading for Specification:
No load
Ripple/Noise (20MHz BW)
See Ordering Guide
Line/Load Regulation See Ordering Guide
Efficiency See Ordering Guide
VOUT Trim Range
(6)
±5% minimum (±10% for T models)
Remote Sense Compensation
±5%
Isolation Voltage:
Input-to-Output 1500Vdc minimum (BASIC)
Isolation Capacitance 650pF
Isolation Resistance 100M
Current Limit Inception (@98%VOUT):
10 Amp Models 12-15 Amps
7.5 Amp Models 8.2-11.5 Amps
5/6 Amp Models 6.5-8.5 Amps
2.5 Amp Models 2.6-4 Amps
2.0 Amp Models 2.1-3 Amps
Short Circuit Current (Hiccup) 1.5-2.3 Amps
All models are tested and specified with a single, external, 0.47µF, multi-layer ceramic output
capacitor and no external input capacitors, unless otherwise noted. All models will effectively
regulate under no-load conditions (with perhaps a slight increase in output ripple/noise).
See Technical Notes/Performance Curves for additional explanations and details.
Input Ripple Current is tested/specified over a 5-20MHz bandwidth with an external 33µF input
capacitor and a simulated source impedance of 220µF and 12µH. See I/O Filtering, Input Ripple
Current and Output Noise for details.
The On/Off Control is designed to be driven with open-collector (or equivalent) logic or the applica-
tion of appropriate voltages (referenced to –Input (pin 2)). Applying a voltage to the On/Off Control
pin when no input voltage is applied to the converter can cause permanent damage. See Remote
On/Off Control for more details.
Extreme Accuracy refers to the accuracy of either trimmed or untrimmed output voltages over all
normal operating ranges and combinations of input voltage, output load and temperature.
Tie the Output Trim pin (pin 9) to +Output (pin 6) for maximum trim down or to –Output (Output
Return/Common, pin 7) for maximum trim up. See Output Trimming for detailed trim equations.
The Current-Limit-Inception point is the output current level at which the converter's power-limiting
circuitry drops the output voltage 2% from its initial value. See Output Current Limiting and
Short-Circuit Protection for more details.
For Start-Up-Time specifications, output settling time is defined as the output voltage having
reached ±1% of its final value at maximum load current.
MTBF’s are calculated using TELCORDIA SR-332 Method 1 Case, ground fixed, +25°C ambient air
and full-load conditions. Contact MPS for demonstrated life-test data.
All models are fully operational and meet all published specifications, including "cold start," at –40°C.
Use only as much output filtering as needed and no more. Larger caps (especially low-ESR ceramic
types) may slow transient response or degrade dynamic performance. Thoroughly test your system
with all components installed.