Datasheet

www.murata-ps.com/support
UEI15 Series
Isolated Wide Input Range 15-Watt DC/DC Converters
MDC_UEI15W.C14 Page 16 of 17
Emissions Performance
Murata Power Solutions measures its products for radio frequency emissions
against the EN 55022 and CISPR 22 standards. Passive resistance loads are
employed and the output is set to the maximum voltage. If you set up your
own emissions testing, make sure the output load is rated at continuous power
while doing the tests.
The recommended external input and output capacitors (if required) are
included. Please refer to the fundamental switching frequency. All of this
information is listed in the Product Specifi cations. An external discrete fi lter is
installed and the circuit diagram is shown below.
[1] Conducted Emissions Parts List
[2] Conducted Emissions Test Equipment Used
Rohde & Schwarz EMI Test Receiver (9KHz – 1000MHz) ESPC
Rohde & Schwarz Software ESPC-1 Ver. 2.20
HP11947A Transient Limiter (Agilent)
OHMITE 25W – Resistor combinations
DC Source Power Supply – Kikisui Model PAD 55-6L
[3] Conducted Emissions Test Results
[4] Layout Recommendations
Most applications can use the fi ltering which is already installed inside the
converter or with the addition of the recommended external capacitors. For
greater emissions suppression, consider additional fi lter components and/or
shielding. Emissions performance will depend on the user’s PC board layout,
the chassis shielding environment and choice of external components. Please
refer to Application Note GEAN02 for further discussion.
Since many factors affect both the amplitude and spectra of emissions, we
recommend using an engineer who is experienced at emissions suppression.
Reference Part Number Description Vendor
L2 PE-62913 1mH, 6A Pulse
L1 500uH,10A, MPS 500uH,10A Murata
C1 Ceramic 2.2ufd, 100V Murata
C2 Electrolytic Capacitor 33ufd, 100V Panasonic
Graph 1. Conducted emissions performance,
CISPR/EN55022, Class B, full load, ltered
Graph 1. Conducted emissions performance,
CISPR/EN55022, Class B, full load, unfi ltered
Figure 8. Conducted Emissions Test Circuit
UEI15-050-Q12P-C EMI 15W Test Card
24Vdc in, 5Vout, 3Amps
V+
V-
Black
Vin - Vout -
Vout +Vin +
Resistive
Load
UUT
L2
L1
C1C1C1C1 C1C1 C2C1C1C1
Resistive
Load
inside a
metal
container