FUNCTIONAL SPECIFICATIONS, UEE-3.3/45-D48
ABSOLUTE MAXIMUM RATINGS
Conditions
Minimum Typical/Nominal Maximum Units
Input Voltage, Continuous 0 80 Vdc
Input Voltage, Transient 100 mS max. duration 100 Vdc
Isolation Voltage Input to output, continuous 2250 Vdc
On/Off Remote Control Power on, referred to -Vin 0 15 Vdc
Output Power 0 151.65 W
Output Current
Current-limited, no damage, short-circuit
protected
0 45.5 A
Storage Temperature Range Vin = Zero (no power) -55 125 °C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifi cations Table is not implied or recommended.
INPUT
Conditions ➀ ➂
Operating Voltage Range 36 48 75 Vdc
Recommended External Fuse Fast blow 10 A
Start-Up Threshold Rising input voltage 33.5 34.5 35.5 Vdc
Undervoltage Shutdown Falling input voltage 32 33 34 Vdc
Overvoltage Shutdown None Vdc
Internal Filter Type Pi
Input Current
Full Load Conditions Vin = nominal 3.4 3.51 A
Low Line Input Current Vin = minimum 4.63 4.79 A
Inrush Transient 0.05 0.1 A
2
-Sec.
Short Circuit Input Current 300 500 mA
No Load Iout = minimum, unit = ON 80 120 mA
Shut-Down Input Current (Off, UV, OT) 710mA
Refl ected (back) ripple current
Measured at input with specifi ed fi lter 20 40 mA, P-P
Pre-biased startup External output voltage < Vset Monotonic
GENERAL and SAFETY
Effi ciency Vin = 48V, full load 91 92 %
Isolation
Isolation Voltage Input to output, continuous 2250 Vdc
Isolation Voltage Input to baseplate, continuous 1500 Vdc
Isolation Voltage Output to baseplate, continuous 1500 Vdc
Insulation Safety Rating basic
Isolation Resistance 10 M
Isolation Capacitance 1000 pF
Safety
Certifi ed to UL-60950-1, CSA-C22.2 No.60950-1,
IEC 60950-1, 2nd edition
Yes
Calculated MTBF
Per Telcordia SR-332, issue 1, class 1, ground
xed, Tcase = +25°C
2.5 Hours x 10
6
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency 400 KHz
Startup Time 610mS
Rise Time 15 25 mS
Dynamic Load Response
50-75-50% load step, settling time to within
±1% of Vout
2500 3000 µSec
Dynamic Load Peak Deviation same as above ±250 ±350 mV
FEATURES and OPTIONS
Remote On/Off Control
“N” suffi x:
Negative Logic, ON state ON = Ground pin or external voltage -0.1 0.8 Vdc
Negative Logic, OFF state OFF = Pin open or external voltage 2.5 15 Vdc
Control Current Open collector/drain 0.2 1 mA
“P” suffi x:
Positive Logic, ON state ON = Pin open or external voltage 2.5 15 V
Positive Logic, OFF state OFF = Ground pin or external voltage 0 1 V
Control Current Open collector/drain 0.2 1 mA
Remote Sense Sense connected to load 10 %
Base Plate "B" suffi x optional
SMT Mounting "M" suffi x optional