Datasheet
www.murata-ps.com/support
TYPICAL PERFORMANCE DATA AND OSCILLOGRAMS, UEE-5/30-D48
0 10203040
70
75
80
85
90
95
100
Load Current (A)
Efficiency (%)
Vin = 75V
Vin = 48V
Vin = 36V
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (ºC)
Output Current (A)
1.0 m/s (200 LFM)
2.0 m/s (400 LFM)
1.5 m/s (300 LFM)
0.5 m/s (100 LFM)
Natural Convection
Maximum Current Temperature Derating at Sea Level
(Vin = 48V, no baseplate. Airfl ow Direction Is Longitudinal from -Vin to +Vin.)
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (ºC)
Output Current (A)
1.0 m/s (200 LFM)
2.0 m/s (400 LFM)
1.5 m/s (300 LFM)
0.5 m/s (100 LFM)
Natural Convection
Maximum Current Temperature Derating at Sea Level
(Vin = 36V, no baseplate. Airfl ow Direction Is Longitudinal from -Vin to +Vin.)
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (ºC)
Output Current (A)
1.0 m/s (200 LFM)
2.0 m/s (400 LFM)
1.5 m/s (300 LFM)
0.5 m/s (100 LFM)
Natural Convection
Maximum Current Temperature Derating at Sea Level
(Vin = 48V, no baseplate. Airfl ow Direction Is Transverse from -Vin to +Vin.)
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (ºC)
Output Current (A)
1.0 m/s (200 LFM)
2.0 m/s (400 LFM)
1.5 m/s (300 LFM)
0.5 m/s (100 LFM)
Natural Convection
Maximum Current Temperature Derating at Sea Level
(Vin = 36V, no baseplate. Airfl ow Direction Is Transverse from -Vin to +Vin.)
Effi ciency vs. Line Voltage and Load Current @ +25°C
UEE 150W Series
Isolated, High-Density, Eighth-Brick
DOSA Low Profi le DC-DC Converters
MDC_UEE 150W_Series.A02 Page 12 of 35