Datasheet

www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
 
F1
External
DC
Power
Source
Reference and
Error Amplifier
-Vout (4)
+Vout (8)
Trim (6)
On/Off
Control
(2)
-Vin (3)
Open = On
+Vin (1)
logic)
Controller
and Power
Barrier
Figure 1. Connection Diagram
Typical topology is shown. Murata Power Solutions recommends an external fuse.
UEE 150W Series
Isolated, High-Density, Eighth-Brick
DOSA Low Profi le DC-DC Converters
MDC_UEE 150W_Series.A02 Page 1 of 35
FEATURES
Synchronous rectifi cation yields high effi ciency
over 90%
36 to 75 Vdc input range (48V nominal)
Outstanding thermal performance and derating
Low profi le 0.42" height with 0.9" x 2.3" outline
dimensions
Fully isolated, 2250 Vdc (BASIC) insulation
Industry standard DOSA eighth-brick pinout and
package and surface mount (SMT) option
Extensive self-protection and short circuit
features
On/Off control, trim and sense functions
Fully protected against temperature and voltage
limits
RoHS-6 compliant
UL/IEC 60950-1 and CAN/CSA C22.2 No. 60950-1,
2nd Edition safety approvals
Monotonic startup into normal and pre-biased
loads
Units are offered with a fi xed output voltage and
current up to 45 Amps. UEEs operate over a wide
temperature range (up to +85 degrees Celsius at
moderate airfl ow) with full rated power. Synchro-
nous rectifi er topology yields excellent effi ciency.
UEEs achieve these impressive mechanical and
environmental specs while delivering excellent
electrical performance in an industry standard
DOSA compatible through-hole package or surface
mount option. The unit is fully protected against
input undervoltage, output overcurrent and short
circuit. An on-board temperature sensor shuts
down the converter if thermal limits are reached
and automatically restarts the converter when the
fault is removed.
An On/Off control input enables phased startup
and shutdown in multi-voltage applications. UEEs
include a Sense input to correct for ohmic losses. A
trim input may be connected to a user’s adjustment
potentiometer or trim resistors for output voltage
calibration.
UEEs include industry-standard safety certifi -
cations and BASIC I/O insulation provides input/
output isolation to 2250V. Radiation and conducted
emission testing is performed to widely accepted
EMC standards.
PRODUCT OVERVIEW
Typical units
For effi cient, fully isolated DC power in the smallest space, the UEE
open frame DC-DC converter series fi t in industry-standard “eighth
brick” outline dimensions and mounting pins (on quarter-brick pinout)
or surface mount option.
Output (V) Current (A) Nominal Input (V)
3.3 45 48
53048
12 12.5 48
Typical units
Fo